[Safety assessment of using collamer phakic implants in the correction of refractive errors].
Polimery W Medycynie 2018 January
BACKGROUND: An increasing number of patients with refractive visual impairments, in whom the correction using spectacles or contact lenses does not meet expectations, consider the possibility of undergoing refractive surgery. Phakic implants are an alternative for patients who are not eligible for laser correction.
OBJECTIVES: The aim of the study is to assess the safety of using collamer phakic implants in the correction of vision defects during the annual follow-up.
MATERIAL AND METHODS: The study included 24 eyes in 12 patients who were implanted with Visian ICL phakic posterior chamber lenses in order to correct myopia. The examinations carried out before the surgery were as follows: objective refractometry, the assessment of distant visual acuity with the best correction, intraocular pressure measurement, evaluation of the endothelium, corneal topography, and depth of the anterior chamber measurement. The final examinations included visual acuity, refraction, intraocular pressure, implant placement, endothelial microscopy, and funduscopic examination.
RESULTS: Mean objective refraction was: sphere -7.77 ±3.55 diopters and cylinder 1.18 ±0.87 diopters. Spectacle correction produced the mean visual acuity of 0.91 ±0.20 (Snellen). During the period of 1-year follow-up, the mean spherical power was 0.475 ±0.39 diopters, cylinder 0.46 ±0.27 diopters and the visual acuity after the procedure 1.05 ±0.22 (Snellen). The results of the 12-month evaluation showed a statistically significant greater improvement in patients using phakic implants compared to those subjected to spectacle correction (p < 0.05). The preand post-operative evaluation demonstrated no significant differences in endothelial cell density (p < 0.05). No complications were reported both during the surgery and the entire follow-up period.
CONCLUSIONS: The results of the safety assessment of using properly implanted ICL phakic lenses show good tolerance of collomer implants in the posterior chamber. They do not have a negative effect on the structures located in the anterior segment of the eye, including the corneal endothelium and the lens.
OBJECTIVES: The aim of the study is to assess the safety of using collamer phakic implants in the correction of vision defects during the annual follow-up.
MATERIAL AND METHODS: The study included 24 eyes in 12 patients who were implanted with Visian ICL phakic posterior chamber lenses in order to correct myopia. The examinations carried out before the surgery were as follows: objective refractometry, the assessment of distant visual acuity with the best correction, intraocular pressure measurement, evaluation of the endothelium, corneal topography, and depth of the anterior chamber measurement. The final examinations included visual acuity, refraction, intraocular pressure, implant placement, endothelial microscopy, and funduscopic examination.
RESULTS: Mean objective refraction was: sphere -7.77 ±3.55 diopters and cylinder 1.18 ±0.87 diopters. Spectacle correction produced the mean visual acuity of 0.91 ±0.20 (Snellen). During the period of 1-year follow-up, the mean spherical power was 0.475 ±0.39 diopters, cylinder 0.46 ±0.27 diopters and the visual acuity after the procedure 1.05 ±0.22 (Snellen). The results of the 12-month evaluation showed a statistically significant greater improvement in patients using phakic implants compared to those subjected to spectacle correction (p < 0.05). The preand post-operative evaluation demonstrated no significant differences in endothelial cell density (p < 0.05). No complications were reported both during the surgery and the entire follow-up period.
CONCLUSIONS: The results of the safety assessment of using properly implanted ICL phakic lenses show good tolerance of collomer implants in the posterior chamber. They do not have a negative effect on the structures located in the anterior segment of the eye, including the corneal endothelium and the lens.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app