We have located links that may give you full text access.
The radiologic assessment of posterior ligamentous complex injury in patients with thoracolumbar fracture.
European Spine Journal 2017 May
PURPOSES: To discuss whether radiologic parameters are closely related to posterior ligamentous complex (PLC) injury identified by magnetic resonance imaging (MRI).
METHODS: One hundred and five thoracolumbar fracture (T11-L2) patients were retrospectively analyzed in the study. The patients were divided into different groups by the status of the PLC on MRI: intact, incompletely ruptured and ruptured. The radiographic parameters included the anterior edge-inferior endplate angle (AEIEA), the anterior edge displacement (AED), the Cobb angle (CA), the region angle (RA), the sagittal index (SI), local kyphosis (LK), the anterior/posterior vertebral height ratio (A/P ratio), the anterior vertebral height ratio (AVH ratio), and bony fragment in front of the fractured vertebra (BFOFV). T test, Pearson's Chi-square and multivariate logistic regression were calculated for the variables.
RESULTS: Supraspinous ligament (SSL) rupture versus intact was not only associated with the occurrence of AEIEA <70°, LK >25° and BFOFV, but also with increased AED (9.89 ± 3.12 mm and 9.34 ± 3.36 mm, P = 0.034), RA (9.52 ± 3.93° versus 7.91 ± 3.99°, P = 0.042), and LK (23.98 ± 5.88° versus 15.55 ± 5.28°, P = 0.021). The indications for interspinous ligament (ISL) injury included AEIEA <75°, AEIEA <70° (P = 0.004 and P < 0.001, respectively), increased AED (P = 0.010), LK >25° (P = 0.024), AVH (P < 0.001), and BFOFV (P < 0.001). Multivariate logistic regression analysis revealed that AEIEA <70° and BFOFV were high risk factors for SSL rupture [standard partial regression coefficients (betas) were 0.439 and 0.408, P = 0.003 and 0.001, respectively] and ISL rupture (betas were 0.548 and 0.494, P = 0.028 and 0.001, respectively). Increased AED and LK >25° were also related to either ISL rupture (P = 0.035 and 0.001, respectively) or SSL rupture (P = 0.014 and 0.008, respectively).
CONCLUSION: Our data may prove useful in a preliminary assessment of the PLC integrity based on plain radiographic imaging. We show that radiologic indications, such as AEIEA <70°, BFOFV, LK >25°, and increased AED, are correlated with ISL or SSL rupture, while RA, CA, SI, A/P ratio, and AVH ratio are not.
METHODS: One hundred and five thoracolumbar fracture (T11-L2) patients were retrospectively analyzed in the study. The patients were divided into different groups by the status of the PLC on MRI: intact, incompletely ruptured and ruptured. The radiographic parameters included the anterior edge-inferior endplate angle (AEIEA), the anterior edge displacement (AED), the Cobb angle (CA), the region angle (RA), the sagittal index (SI), local kyphosis (LK), the anterior/posterior vertebral height ratio (A/P ratio), the anterior vertebral height ratio (AVH ratio), and bony fragment in front of the fractured vertebra (BFOFV). T test, Pearson's Chi-square and multivariate logistic regression were calculated for the variables.
RESULTS: Supraspinous ligament (SSL) rupture versus intact was not only associated with the occurrence of AEIEA <70°, LK >25° and BFOFV, but also with increased AED (9.89 ± 3.12 mm and 9.34 ± 3.36 mm, P = 0.034), RA (9.52 ± 3.93° versus 7.91 ± 3.99°, P = 0.042), and LK (23.98 ± 5.88° versus 15.55 ± 5.28°, P = 0.021). The indications for interspinous ligament (ISL) injury included AEIEA <75°, AEIEA <70° (P = 0.004 and P < 0.001, respectively), increased AED (P = 0.010), LK >25° (P = 0.024), AVH (P < 0.001), and BFOFV (P < 0.001). Multivariate logistic regression analysis revealed that AEIEA <70° and BFOFV were high risk factors for SSL rupture [standard partial regression coefficients (betas) were 0.439 and 0.408, P = 0.003 and 0.001, respectively] and ISL rupture (betas were 0.548 and 0.494, P = 0.028 and 0.001, respectively). Increased AED and LK >25° were also related to either ISL rupture (P = 0.035 and 0.001, respectively) or SSL rupture (P = 0.014 and 0.008, respectively).
CONCLUSION: Our data may prove useful in a preliminary assessment of the PLC integrity based on plain radiographic imaging. We show that radiologic indications, such as AEIEA <70°, BFOFV, LK >25°, and increased AED, are correlated with ISL or SSL rupture, while RA, CA, SI, A/P ratio, and AVH ratio are not.
Full text links
Trending Papers
Monitoring Macro- and Microcirculation in the Critically Ill: A Narrative Review.Avicenna Journal of Medicine 2023 July
ASA Consensus-based Guidance on Preoperative Management of Patients on Glucagon-like Peptide-1 Receptor Agonists.Anesthesiology 2023 November 21
Common postbariatric surgery emergencies for the acute care surgeon: What you need to know.Journal of Trauma and Acute Care Surgery 2023 December 2
Sodium bicarbonate Ringer's solution for hemorrhagic shock: A meta-analysis comparing crystalloid solutions.American Journal of Emergency Medicine 2023 November 6
Association between postinduction hypotension and postoperative mortality: a single-centre retrospective cohort study.Canadian Journal of Anaesthesia 2023 November 22
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app