COMPARATIVE STUDY
JOURNAL ARTICLE
META-ANALYSIS
RESEARCH SUPPORT, NON-U.S. GOV'T
REVIEW
SYSTEMATIC REVIEW
Ultrasound versus magnetic resonance imaging for Morton neuroma: systematic review and meta-analysis.
European Radiology 2015 August
OBJECTIVES: To compare ultrasound (US) and magnetic resonance imaging (MRI) in the diagnosis of Morton's neuroma.
METHODS: Studies that assessed the diagnostic accuracy of US and MRI for Morton's neuroma were retrieved from major medical libraries independently by two reviewers up to 1 April 2014. Predefined inclusion and exclusion criteria were adopted.
RESULTS: 277 studies were initially found, and the meta-analysis was conducted on 14 studies. US sensitivity was studied in five studies, MRI sensitivity in three studies, and bothin six studies. All studies used surgery as the reference standard. A high sensitivity (SE) of diagnostic testing was observed for both US (SE (95 % CI) = 0.91 (0.83-0.96)) and MRI (SE (95 % CI) = 0.90 (0.82-0.96)) with no significant differences between the two modalities in diagnosis (Q test p = 0.88). For MRI, specificity of test was 1.00 with a pooled estimation of 1.00 (0.73-1.00), while the pooled specificity was 0.854 (95 % CI: 0.41-1.00) for US. No differences were observed between US and MRI in study design (p = 0.76).
CONCLUSION: This meta-analysis shows that the SE of US (0.91) is equal to (p = 0.88) that of MRI (0.90) for identification of Morton's neuroma.
KEY POINTS: • For Morton's neuroma, US sensitivity is equal to MRI. • US is as accurate as MRI in diagnosing Morton's neuroma. • US may be the most cost-effective imaging method for Morton's neuroma.
METHODS: Studies that assessed the diagnostic accuracy of US and MRI for Morton's neuroma were retrieved from major medical libraries independently by two reviewers up to 1 April 2014. Predefined inclusion and exclusion criteria were adopted.
RESULTS: 277 studies were initially found, and the meta-analysis was conducted on 14 studies. US sensitivity was studied in five studies, MRI sensitivity in three studies, and bothin six studies. All studies used surgery as the reference standard. A high sensitivity (SE) of diagnostic testing was observed for both US (SE (95 % CI) = 0.91 (0.83-0.96)) and MRI (SE (95 % CI) = 0.90 (0.82-0.96)) with no significant differences between the two modalities in diagnosis (Q test p = 0.88). For MRI, specificity of test was 1.00 with a pooled estimation of 1.00 (0.73-1.00), while the pooled specificity was 0.854 (95 % CI: 0.41-1.00) for US. No differences were observed between US and MRI in study design (p = 0.76).
CONCLUSION: This meta-analysis shows that the SE of US (0.91) is equal to (p = 0.88) that of MRI (0.90) for identification of Morton's neuroma.
KEY POINTS: • For Morton's neuroma, US sensitivity is equal to MRI. • US is as accurate as MRI in diagnosing Morton's neuroma. • US may be the most cost-effective imaging method for Morton's neuroma.
Full text links
Trending Papers
How to improve the efficiency and the safety of real-time ultrasound-guided central venous catheterization in 2023: a narrative review.Annals of Intensive Care 2023 May 26
SGLT2 Inhibitors: A New Therapeutical Strategy to Improve Clinical Outcomes in Patients with Chronic Kidney Diseases.International Journal of Molecular Sciences 2023 May 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app