Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.
BACKGROUND: We report the results of cementless total hip arthroplasty with a tapered, rectangular titanium stem that was introduced in 1979 and continues to be used today with only minor changes. The aim of the design is to achieve primary stability to resist rotational and axial forces through precision rasping and press-fit implantation of a tapered, rectangular femoral component.
METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years).
RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00).
CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.
METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years).
RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00).
CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.
Full text links
Related Resources
Trending Papers
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Prevention and treatment of ischaemic and haemorrhagic stroke in people with diabetes mellitus: a focus on glucose control and comorbidities.Diabetologia 2024 April 17
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Eosinophilic Esophagitis: Clinical Pearls for Primary Care Providers and Gastroenterologists.Mayo Clinic Proceedings 2024 April
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app