STUDY OBJECTIVES: To assess the effectiveness of pulse oximetry and radioisotope measurement of right-to-left (R-L) shunt for the early detection of pulmonary arteriovenous malformations (PAVMs) in patients with hereditary hemorrhagic telangiectasia (HHT).
DESIGN: Patients with HHT had serial measurements of the following: (1) arterial oxygen saturation (SaO2) by pulse oximetry in erect and supine positions, and on maximal exercise using cycle ergometry; (2) quantitative radioisotope measurements of R-L shunt using IV 99mTc-labeled macroaggregates of albumin; and (3) routine pulmonary function. After percutaneous transcatheter embolization of all PAVMs with feeding vessel diameters > 3 mm, residual PAVMs were assessed with selective digital subtraction pulmonary angiography. Using postembolization angiography as the "gold standard," SaO2 and radioisotope shunt measurements after embolization were analyzed retrospectively using logistic regression to assess the ability of each test to predict for the presence of residual PAVMs.
RESULTS: Of the 66 patients included, 40 had small PAVMs remaining postembolization. Using univariate logistic regression, radioisotope shunt and erect saturation showed a significant relationship with the presence of residual PAVMs (p=0.001, 0.005, respectively). Erect SaO2 < or = 96% had 73% sensitivity and 35% specificity for detecting PAVMs. Radioisotope shunt >3.5% of cardiac output had 87% sensitivity and 61% specificity for detecting PAVMs.
CONCLUSIONS: These results confirm that noninvasive measurements are useful in the screening of patients with HHT for the presence of PAVMs without need for angiography and its associated risks, and that radionuclide scanning is better than pulse oximetry.
DESIGN: Patients with HHT had serial measurements of the following: (1) arterial oxygen saturation (SaO2) by pulse oximetry in erect and supine positions, and on maximal exercise using cycle ergometry; (2) quantitative radioisotope measurements of R-L shunt using IV 99mTc-labeled macroaggregates of albumin; and (3) routine pulmonary function. After percutaneous transcatheter embolization of all PAVMs with feeding vessel diameters > 3 mm, residual PAVMs were assessed with selective digital subtraction pulmonary angiography. Using postembolization angiography as the "gold standard," SaO2 and radioisotope shunt measurements after embolization were analyzed retrospectively using logistic regression to assess the ability of each test to predict for the presence of residual PAVMs.
RESULTS: Of the 66 patients included, 40 had small PAVMs remaining postembolization. Using univariate logistic regression, radioisotope shunt and erect saturation showed a significant relationship with the presence of residual PAVMs (p=0.001, 0.005, respectively). Erect SaO2 < or = 96% had 73% sensitivity and 35% specificity for detecting PAVMs. Radioisotope shunt >3.5% of cardiac output had 87% sensitivity and 61% specificity for detecting PAVMs.
CONCLUSIONS: These results confirm that noninvasive measurements are useful in the screening of patients with HHT for the presence of PAVMs without need for angiography and its associated risks, and that radionuclide scanning is better than pulse oximetry.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app