JOURNAL ARTICLE
Evaluation of different criteria for the separation of pleural transudates from exudates.
Chest 1993 August
OBJECTIVES: To determine the relative usefulness of different criteria for the separation of pleural transudates from exudates.
DESIGN: Prospective evaluation of patients referred for thoracentesis.
SETTING: Community teaching hospital.
PATIENTS: Three hundred fifty-one consecutive patients with pleural effusions referred for thoracentesis. Fifty-four of these patients were excluded from the analysis.
MEASUREMENTS: We recorded clinical characteristics and final diagnosis and measured pleural fluid and serum levels of total protein, lactate dehydrogenase, and cholesterol. All patients included were followed up until final diagnosis. MEAN RESULTS: Forty-four (15 percent) pleural effusions were transudates and 253 (85 percent) were exudates. The criteria of Light et al, with a sensitivity of 98 percent and a specificity of 77 percent for exudates, showed the best accuracy (95.2 percent). Moreover, when the cutoff used for the criteria of Light et al was modified according to our own laboratory results, specificity rose to 93 percent with almost a similar accuracy (94 percent). Protein pleural fluid/serum ratio > 0.5 and pleural fluid cholesterol > 60 mg/dl showed equal specificity (91 percent), but the former had better sensitivity for exudates (88 percent vs 81 percent).
CONCLUSIONS: When the proportion of exudates included is 85 percent or more, as in the present series, the criteria of Light et al remain the method that offers the highest accuracy for segregating transudates from exudates.
DESIGN: Prospective evaluation of patients referred for thoracentesis.
SETTING: Community teaching hospital.
PATIENTS: Three hundred fifty-one consecutive patients with pleural effusions referred for thoracentesis. Fifty-four of these patients were excluded from the analysis.
MEASUREMENTS: We recorded clinical characteristics and final diagnosis and measured pleural fluid and serum levels of total protein, lactate dehydrogenase, and cholesterol. All patients included were followed up until final diagnosis. MEAN RESULTS: Forty-four (15 percent) pleural effusions were transudates and 253 (85 percent) were exudates. The criteria of Light et al, with a sensitivity of 98 percent and a specificity of 77 percent for exudates, showed the best accuracy (95.2 percent). Moreover, when the cutoff used for the criteria of Light et al was modified according to our own laboratory results, specificity rose to 93 percent with almost a similar accuracy (94 percent). Protein pleural fluid/serum ratio > 0.5 and pleural fluid cholesterol > 60 mg/dl showed equal specificity (91 percent), but the former had better sensitivity for exudates (88 percent vs 81 percent).
CONCLUSIONS: When the proportion of exudates included is 85 percent or more, as in the present series, the criteria of Light et al remain the method that offers the highest accuracy for segregating transudates from exudates.
Full text links
Trending Papers
Diabetic kidney disease in type 2 diabetes: a consensus statement from the Swiss Societies of Diabetes and Nephrology.Swiss Medical Weekly 2023 January 7
Systemic complications of rheumatoid arthritis: Focus on pathogenesis and treatment.Frontiers in Immunology 2022
Migraine.Annals of Internal Medicine 2023 January 11
Long COVID: major findings, mechanisms and recommendations.Nature Reviews. Microbiology 2023 January 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app