Journal of Perinatal Medicine 2024 March 29
OBJECTIVES: Fetoscopic laser coagulation of placental anastomoses is usually performed for a treatment of twin-to-twin transfusion syndrome (TTTS). A common complication of fetoscopic laser coagulation for TTTS is preterm preliminary rupture of fetal membranes (PPROM) aggravating the neonatal outcome significantly. However, use of an flexible 1 mm fetoscope with an curved sheath could reduce iatrogenic damage of the amniotic membrane and improve neonatal outcomes after laser treatment. The aim of this study was to compare neonatal outcomes using this flexible fetoscope with curved sheath vs. use of a standard lens technique.
METHODS: Outcomes were retrospective analyzed after use of a standard lens fetoscope of 2 mm (sheath 6.63 mm2 or 11.27 mm2 for anterior placenta) and a flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2 ) in two German centers of fetal surgery, performed during 2006-2019.
RESULTS: Neonatal outcome of 247 TTTS patients were analyzed including the rates of double and single fetal survival. The survival of at least one fetus was 97.2 % in the group with the ultrathin technique (n=154) compared to 88.3 % (n=93) in the group with the standard lens fetoscope (p=0.008). Survival of both fetuses was not different between groups (81.0 vs. 75.3 %). The procedure to delivery interval was significantly increased using the ultrathin fetoscope (89.1±35.0 d vs. 71.4±35.4 d, p=0.001) resulting in an increased gestational age at delivery by 11 days on average (231.9±28.1 d vs. 221.1±32.7 d, p=0.012).
CONCLUSIONS: Fetal survival can be significantly increased following TTTS using flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2 ).
METHODS: Outcomes were retrospective analyzed after use of a standard lens fetoscope of 2 mm (sheath 6.63 mm2 or 11.27 mm2 for anterior placenta) and a flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2 ) in two German centers of fetal surgery, performed during 2006-2019.
RESULTS: Neonatal outcome of 247 TTTS patients were analyzed including the rates of double and single fetal survival. The survival of at least one fetus was 97.2 % in the group with the ultrathin technique (n=154) compared to 88.3 % (n=93) in the group with the standard lens fetoscope (p=0.008). Survival of both fetuses was not different between groups (81.0 vs. 75.3 %). The procedure to delivery interval was significantly increased using the ultrathin fetoscope (89.1±35.0 d vs. 71.4±35.4 d, p=0.001) resulting in an increased gestational age at delivery by 11 days on average (231.9±28.1 d vs. 221.1±32.7 d, p=0.012).
CONCLUSIONS: Fetal survival can be significantly increased following TTTS using flexible fetoscope of 1 mm or 1.2 mm (sheath 2.65 mm2 or 3.34 mm2 ).
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app