Add like
Add dislike
Add to saved papers

Aluminum and other chemical elements in parenteral nutrition components and all-in-one admixtures.

Clinical Nutrition 2023 December
BACKGROUND & AIMS: Parenteral nutrition (PN) can lead to high or even toxic exposure to aluminum (Al). We aimed to quantify concentrations of Al and other chemical elements of all-in-one (AIO) PN admixtures for adults prepared from commercial multichamber bags (Olimel® 5.7%, Omegaflex® special, SmofKabiven®, all with and without electrolytes) and vitamin and trace element additives over a 48-h period. Secondly, we determined the level of Al contamination resulting from admixing and infusion set use.

METHODS: We used dynamic reaction cell and kinetic energy discrimination inductively coupled plasma mass spectrometry (ICP-MS) to quantify Al, arsenic (As), cadmium (Cd), cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni), antimony (Sb), selenium (Se), tin (Sn), vanadium (V), and zinc (Zn) in AIO PN admixtures. We extracted samples for analysis via the bag injection ports and infusion sets over a 48-h period after admixing. We compared the measured Al concentrations of AIO PN admixtures with calculated values based on the measured concentrations of individual chamber contents and additives.

RESULTS: Mean (standard deviation) baseline Al concentrations in AIO PN admixtures ranged from 10.5 (0.5) to 59.3 (11.4) μg/L and decreased slightly over the 48 h (estimate [standard error] -0.09 [0.02] μg/L/hour, p <0.001). Thus, certain products exceeded the widely accepted limit of 25 μg/L. There was no significant difference in Al concentrations between samples extracted via the bag injection ports or infusion sets (p = 0.33), nor between measured and calculated Al concentrations of AIO PN admixtures (p = 0.91).

CONCLUSION: Because certain commercially available PN admixtures for adults proved to contain excessively high levels of Al in our study, regulations and corresponding quality requirements at the authority level (e.g., Pharmacopoeia and regulatory authorities) are urgently required. Our results showed that the PN handling process (admixing and supplementing additives) or the materials of the infusion set did not lead to additional Al contamination to any extent. Moreover, calculated Al concentrations of AIO PN admixtures derived from individual chamber contents and additives are valid.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app