Add like
Add dislike
Add to saved papers

Assessing the frequency and types of errors involved in the use of a modified intravenous N-acetylcysteine protocol for acetaminophen overdose.

CJEM 2024 March
BACKGROUND: Acetaminophen overdose is a leading cause of acute liver failure in developing countries. N-acetylcysteine (NAC) is a highly effective antidote for acetaminophen hepatotoxicity, typically initiated in the emergency department. Due to a known high rate of errors with the standard three-bag IV NAC protocol, in 2019, the Ontario Poison Center changed to a modified 3% IV NAC one-bag protocol. This study was undertaken to determine the frequency and types of errors associated with the use of this protocol.

METHODS: Data were gathered via chart review of Ontario Poison Centre electronic medical record cases identified as receiving IV NAC for acetaminophen overdose between August 1 and September 30, 2022. 218 total charts were identified, and 188 were deemed eligible based on inclusion and exclusion criteria.

RESULTS: Errors were identified in 25% of charts, consisting of dosing errors in 11.7%, stopping errors in 9.0%, initiation errors in 3.7%, and interruptions in therapy in 3.2%. Dosing errors were the most common type of error (44.4%), with overdoses occurring three times more than underdoses. Errors were identified at 39% of geographic locations in the charts reviewed, with similar frequency in Ontario, Manitoba, and Nunavut. Clinical outcomes were similar in charts with and without errors.

INTERPRETATION: The rate of errors identified with this 3% IV NAC one-bag protocol is lower than reported for the standard three-bag protocol, but remains high due to dosing errors. Previously reported issues with prolonged interruptions in therapy with the standard three-bag protocol were low with the current 3% one-bag protocol. Although severe outcomes are rare, IV NAC overdose can be fatal. Identifying local factors in emergency departments that can contribute to administration errors (i.e., dose calculation, pump programming issues) can enhance the safety of this important antidote.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app