Add like
Add dislike
Add to saved papers

Psychometric Validation of the ViSIO-PRO and ViSIO-ObsRO in Retinitis Pigmentosa and Leber Congenital Amaurosis.

Ophthalmology and Therapy 2023 Februrary 28
INTRODUCTION: Retinitis Pigmentosa (RP) and Leber Congenital Amaurosis (LCA) are rare inherited retinal degenerative disorders. The Visual Symptom and Impact Outcomes patient-reported outcome (ViSIO-PRO) and observer-reported outcome (ViSIO-ObsRO) instruments were developed in this population to assess visual function symptoms and impacts on vision-dependent activities of daily living (ADL) and distal health-related quality of life (HRQoL). This study aimed to explore the psychometric properties of the ViSIO-PRO and ViSIO-ObsRO in RP/LCA.

METHODS: The 49-item ViSIO-PRO and 27-item ViSIO-ObsRO instruments were completed by 83 adult and adolescent patients and 22 caregivers of child patients aged 3-11 years with RP/LCA, respectively, at baseline and 12-16-day follow-up. Concurrent measures were also administered at baseline. Psychometric analyses assessed item (question) properties, dimensionality, scoring, reliability, validity, and score interpretation.

RESULTS: Item responses were mainly evenly distributed across the response scale, and inter-item correlations were mostly moderate to strong (> 0.30) at baseline within hypothesized domains. Item deletion was informed by item properties, qualitative data, and clinical input and supported retention of 35 ViSIO-PRO items and 25 ViSIO-ObsRO items. Confirmatory factor analysis in line with pre-hypothesized domains supported a four-factor model assessing visual function symptoms, mobility, vision-dependent ADL, and distal HRQoL. A bifactor model supported calculation of total scores and four domain scores. Internal consistency was high for domain and total scores (Cronbach's alpha > 0.70) and test-retest reliability for total scores was strong between baseline and 12-16-day follow-up (intraclass correlation coefficients 0.66-0.98). Convergent validity was supported by strong correlations in a logical pattern with concurrent measures. Mean baseline scores differed significantly between severity groups. Distribution-based methods provided initial insights to guide interpretation of scores.

CONCLUSIONS: Findings supported item reduction and established scoring of the instruments. Evidence of reliability and validity as outcome measures in RP/LCA was also reported. Further research is ongoing to explore responsiveness of the ViSIO-PRO and ViSIO-ObsRO instruments and interpretation of change scores.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app