Comparison of flash glucose monitoring with real time continuous glucose monitoring in children and adolescents with type 1 diabetes treated with continuous subcutaneous insulin infusion.
Diabetes Research and Clinical Practice 2019 June
AIMS: In 2016 intermittently scanned continuous glucose monitoring (isCGM) became the first reimbursed CGM system in Belgium. Many children with type 1 diabetes (T1D) treated with multiple daily injections as well as with continuous subcutaneous insulin infusion (CSII) switched from self-monitoring of blood glucose to isCGM to monitor their treatment. In 2017 the Enlite® real-time CGM (rtCGM) system was reimbursed enabling its use with the Minimed® 640G insulin pump with integrated SmartGuard technology. In this study we compared the metabolic control during CSII with isCGM with that during rtCGM. Patient's satisfaction and side effects of the rtCGM system were also evaluated.
METHODS: 20 children with T1D, aged 5-16 years, were included. Metabolic control during the last month of isCGM use was compared to that during the 3rd and 6th month of rtCGM.
RESULTS: Three patients stopped early rtCGM mainly due to calibration burden. The HbA1c level and the mean glucose value in the other patients did not change after switching to the rtCGM system. Glucose variability was smaller (46.2% vs 38.4% and 36.4%, p = 0.000). Time in hypoglycemia (<70 mg/dl) was lower (7.4% vs 1.6% and 1.5%, p = 0.000). The main patient inconvenience was the sensor calibration.
CONCLUSIONS: Our data show that during Enlite® rtCGM with the Minimed® 640G pump system glucose variability was smaller and the patients spent less time in hypoglycemia than during isCGM. The need for timely calibrations is considered as the main drawback of the system.
METHODS: 20 children with T1D, aged 5-16 years, were included. Metabolic control during the last month of isCGM use was compared to that during the 3rd and 6th month of rtCGM.
RESULTS: Three patients stopped early rtCGM mainly due to calibration burden. The HbA1c level and the mean glucose value in the other patients did not change after switching to the rtCGM system. Glucose variability was smaller (46.2% vs 38.4% and 36.4%, p = 0.000). Time in hypoglycemia (<70 mg/dl) was lower (7.4% vs 1.6% and 1.5%, p = 0.000). The main patient inconvenience was the sensor calibration.
CONCLUSIONS: Our data show that during Enlite® rtCGM with the Minimed® 640G pump system glucose variability was smaller and the patients spent less time in hypoglycemia than during isCGM. The need for timely calibrations is considered as the main drawback of the system.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app