Add like
Add dislike
Add to saved papers

The Siconolfi step test: a valid and reliable assessment of cardiopulmonary fitness in older men with prostate cancer.

Background: Assessing fitness and promoting regular physical activity can improve health outcomes and early recovery in prostate cancer. This is however, underutilised in clinical practice. The cardiopulmonary exercise test (CPET) is increasingly being used pre-treatment to measure aerobic capacity and peak oxygen consumption (VO2 peak - a gold standard in cardiopulmonary fitness assessment). However, CPET requires expensive equipment and may not always be appropriate. The Siconolfi step test (SST) is simpler and cheaper, and could provide an alternative.The aim of this study was to evaluate the validity and reliability of SST for predicting cardiopulmonary fitness in men with prostate cancer. Men were recruited to this two-centre study (Surrey and Newcastle, United Kingdom) after treatment for locally advanced prostate cancer. They had one or more of three risk factors: elevated blood pressure, overweight (BMI > 25), or androgen deprivation therapy (ADT). Cardiopulmonary fitness was measured using SST and cycle ergometry CPET, at two visits three months apart. The validity of SST was assessed by comparing it to CPET. The VO2 peak predicted from SST was compared to the VO2 peak directly measured with CPET. The reliability of SST was assessed by comparing repeated measures. Bland-Altman analysis was used to derive limits of agreement in validity and reliability analysis.

Results: Sixty-six men provided data for both SST and CPET. These data were used for validity analysis. 56 men provided SST data on both visits. These data were used for reliability analysis. SST provided valid prediction of the cardiopulmonary fitness in men > 60 years old. The average difference between CPET and SST was 0.64 ml/kg/min with non-significant positive bias towards CPET ( P  = 0.217). Bland-Altman 95% limits of agreement of SST with CPET were ± 7.62 ml/kg/min. SST was reliable across the whole age range. Predicted VO2 peak was on average 0.53 ml/kg/min higher at Visit 2 than at Visit 1 ( P  = 0.181). Bland-Altman 95% limits of agreement between repeated SST measures were ± 5.84 ml/kg/min.

Conclusions: SST provides a valid and reliable alternative to CPET for the assessment of cardiopulmonary fitness in older men with prostate cancer. Caution is advised when assessing men 60 years old or younger because the VO2 peak predicted with SST was significantly lower than that measured with CPET.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app