Carotid Artery Stiffness Assessment by Ultrafast Ultrasound Imaging: Feasibility and Potential Influencing Factors.
Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine 2018 April 20
OBJECTIVES: To evaluate the feasibility of the ultrafast ultrasound pulsed wave velocity (PWV) for carotid stiffness assessment and potential influencing factors.
METHODS: Ultrafast PWV measurements of 442 carotid arteries in 162 consecutive patients (patient group) and 66 healthy volunteers (control group) were performed. High- and very high-frequency transducers were used in 110 carotid segments. The ultrafast PWVs at the beginning and end of systole were automatically measured. The correlations between the intima-media thickness (IMT) and ultrafast PWV and the equipment and carotid factors influencing the utility of ultrafast PWV were analyzed.
RESULTS: Each ultrafast PWV acquisition was completed within 1 minute. The intraobserver variability showed mean differences ± SD of 0.12 ± 1.28 m/s for the PWV before systole and 0.06 ± 1.30 m/s for the PWV at the end of systole. Ultrafast PWV measurements were more likely obtained with the very high- frequency transducer when the IMT was less than 1.5 mm (P < .05). A generalized linear mixed-effects model analysis showed that the very high-frequency transducer had a greater ability to obtain a valid carotid ultrafast PWV measurement with an IMT of less than 1.5 mm (P < .05). The IMT was positively correlated with the PWV before systole and at the end of systole (r = 0.207-0.771; all P < .05) in the control group, patient group, and carotid subgroup with an IMT of less than 1.5 mm. A multiple regression analysis showed that the IMT and plaque were important independent factors in predicting failure of the ultrafast PWV (P < .001).
CONCLUSIONS: The ultrafast PWV is an effective and user-friendly method for evaluating carotid stiffness. The IMT and transducer type are factors influencing the ability to obtain an ultrafast PWV measurement.
METHODS: Ultrafast PWV measurements of 442 carotid arteries in 162 consecutive patients (patient group) and 66 healthy volunteers (control group) were performed. High- and very high-frequency transducers were used in 110 carotid segments. The ultrafast PWVs at the beginning and end of systole were automatically measured. The correlations between the intima-media thickness (IMT) and ultrafast PWV and the equipment and carotid factors influencing the utility of ultrafast PWV were analyzed.
RESULTS: Each ultrafast PWV acquisition was completed within 1 minute. The intraobserver variability showed mean differences ± SD of 0.12 ± 1.28 m/s for the PWV before systole and 0.06 ± 1.30 m/s for the PWV at the end of systole. Ultrafast PWV measurements were more likely obtained with the very high- frequency transducer when the IMT was less than 1.5 mm (P < .05). A generalized linear mixed-effects model analysis showed that the very high-frequency transducer had a greater ability to obtain a valid carotid ultrafast PWV measurement with an IMT of less than 1.5 mm (P < .05). The IMT was positively correlated with the PWV before systole and at the end of systole (r = 0.207-0.771; all P < .05) in the control group, patient group, and carotid subgroup with an IMT of less than 1.5 mm. A multiple regression analysis showed that the IMT and plaque were important independent factors in predicting failure of the ultrafast PWV (P < .001).
CONCLUSIONS: The ultrafast PWV is an effective and user-friendly method for evaluating carotid stiffness. The IMT and transducer type are factors influencing the ability to obtain an ultrafast PWV measurement.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.