We have located links that may give you full text access.
Innovative methodology for point-of-care circulating cathodic antigen with rapid urine concentration for use in the field for detecting low Schistosoma mansoni infection and for control of cure with high accuracy.
Background: Prior to eliminating schistosomiasis, efforts must address accurate and fast individual diagnosis. Diagnosis is still inaccurate by parasitological and point-of-care circulating cathodic antigen (POC-CCA) in areas of low endemicity.
Methods: Our group has optimized POC-CCA with a 30 min urine concentration step with no need for specialized technicians or equipment and with high accuracy. We evaluated this new method, called POC-CCA filter (FLT), in two Brazilian endemic areas with distinct profiles.
Results: At baseline, POC-CCA had a poor performance with several false results and undefined trace readings, revealing a prevalence rate of 10% against a rate of 23% for POC-CCA FLT, which was similar to the parasitological rates. Accuracy increased from as low as 0.36 to 0.96 after urine concentration in one area. POC-CCA properly diagnosed only half of the cases at three post-treatment time points, while POC-CCA FLT was able to diagnose 96, 83 and 100%, respectively.
Conclusions: The improvement of conventional POC methodology by a fast and simple urine concentration step provided not only an increase in its accuracy before and after praziquantel treatment, but also preserved its applicability in low-prevalence endemic areas, allowing the definition of trace readings as negative cases.
Methods: Our group has optimized POC-CCA with a 30 min urine concentration step with no need for specialized technicians or equipment and with high accuracy. We evaluated this new method, called POC-CCA filter (FLT), in two Brazilian endemic areas with distinct profiles.
Results: At baseline, POC-CCA had a poor performance with several false results and undefined trace readings, revealing a prevalence rate of 10% against a rate of 23% for POC-CCA FLT, which was similar to the parasitological rates. Accuracy increased from as low as 0.36 to 0.96 after urine concentration in one area. POC-CCA properly diagnosed only half of the cases at three post-treatment time points, while POC-CCA FLT was able to diagnose 96, 83 and 100%, respectively.
Conclusions: The improvement of conventional POC methodology by a fast and simple urine concentration step provided not only an increase in its accuracy before and after praziquantel treatment, but also preserved its applicability in low-prevalence endemic areas, allowing the definition of trace readings as negative cases.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app