EZSCAN for undiagnosed type 2 diabetes mellitus: A systematic review and meta-analysis.
PloS One 2017
OBJECTIVES: The EZSCAN is a non-invasive device that, by evaluating sweat gland function, may detect subjects with type 2 diabetes mellitus (T2DM). The aim of the study was to conduct a systematic review and meta-analysis including studies assessing the performance of the EZSCAN for detecting cases of undiagnosed T2DM.
METHODOLOGY/PRINCIPAL FINDINGS: We searched for observational studies including diagnostic accuracy and performance results assessing EZSCAN for detecting cases of undiagnosed T2DM. OVID (Medline, Embase, Global Health), CINAHL and SCOPUS databases, plus secondary resources, were searched until March 29, 2017. The following keywords were utilized for the systematic searching: type 2 diabetes mellitus, hyperglycemia, EZSCAN, SUDOSCAN, and sudomotor function. Two investigators extracted the information for meta-analysis and assessed the quality of the data using the Revised Version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist. Pooled estimates were obtained by fitting the logistic-normal random-effects model without covariates but random intercepts and using the Freeman-Tukey Arcsine Transformation to stabilize variances. Heterogeneity was also assessed using the I2 measure. Four studies (n = 7,720) were included, three of them used oral glucose tolerance test as the gold standard. Using Hierarchical Summary Receiver Operating Characteristic model, summary sensitivity was 72.0% (95%CI: 60.0%- 83.0%), whereas specificity was 56.0% (95%CI: 38.0%- 74.0%). Studies were very heterogeneous (I2 for sensitivity: 79.2% and for specificity: 99.1%) regarding the inclusion criteria and bias was present mainly due to participants selection.
CONCLUSIONS: The sensitivity of EZSCAN for detecting cases of undiagnosed T2DM seems to be acceptable, but evidence of high heterogeneity and participant selection bias was detected in most of the studies included. More studies are needed to evaluate the performance of the EZSCAN for undiagnosed T2DM screening, especially at the population level.
METHODOLOGY/PRINCIPAL FINDINGS: We searched for observational studies including diagnostic accuracy and performance results assessing EZSCAN for detecting cases of undiagnosed T2DM. OVID (Medline, Embase, Global Health), CINAHL and SCOPUS databases, plus secondary resources, were searched until March 29, 2017. The following keywords were utilized for the systematic searching: type 2 diabetes mellitus, hyperglycemia, EZSCAN, SUDOSCAN, and sudomotor function. Two investigators extracted the information for meta-analysis and assessed the quality of the data using the Revised Version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist. Pooled estimates were obtained by fitting the logistic-normal random-effects model without covariates but random intercepts and using the Freeman-Tukey Arcsine Transformation to stabilize variances. Heterogeneity was also assessed using the I2 measure. Four studies (n = 7,720) were included, three of them used oral glucose tolerance test as the gold standard. Using Hierarchical Summary Receiver Operating Characteristic model, summary sensitivity was 72.0% (95%CI: 60.0%- 83.0%), whereas specificity was 56.0% (95%CI: 38.0%- 74.0%). Studies were very heterogeneous (I2 for sensitivity: 79.2% and for specificity: 99.1%) regarding the inclusion criteria and bias was present mainly due to participants selection.
CONCLUSIONS: The sensitivity of EZSCAN for detecting cases of undiagnosed T2DM seems to be acceptable, but evidence of high heterogeneity and participant selection bias was detected in most of the studies included. More studies are needed to evaluate the performance of the EZSCAN for undiagnosed T2DM screening, especially at the population level.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app