Patient-specific quantification of image quality: An automated technique for measuring the distribution of organ Hounsfield units in clinical chest CT images.
Medical Physics 2017 September
PURPOSE: To develop and validate an automated technique for measuring organ Hounsfield units (HUs) in clinical chest CT images.
MATERIALS AND METHODS: An automated computer algorithm was developed to measure the distribution of HUs inside four major organs: the lungs, liver, aorta, and spine. These organs were first identified using image processing techniques. Each organ was segmented into multiple regions of interest (ROIs) and characterized in terms of HU values. The medians of the ROI histograms were computed for each dataset. The automated results were validated by assessing their correlation with manual measurements in fifteen contrast-enhanced and fifteen non-contrast-enhanced clinical chest CT datasets. The robustness of the measurements with respect to dependency on image noise and CTDIvol was ascertained. One utility of the approach was further demonstrated in assessing the variability in aorta HUs across 732 patients undergoing noncontrast and contrast-enhanced examinations.
RESULTS: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast-enhanced chest CT exams. The automated measurements were in agreement with manual measurements with a near unity slope of the relationship between automated and manual measurements with high coefficient of determination (slope = 0.931-1.003, R2 = 0.89-0.99). Organ median HU measurements were found to be largely independent of both image noise and CTDIvol (P > 0.05), as expected. Across patient cases, the program ran successfully across 95% (697/732) of cases. Aorta median HUs demonstrated five times more variability in contrast-enhanced exams compared to that in non-contrast-enhanced exams.
CONCLUSIONS: Patient-specific organ HUs can be measured from clinical datasets. The algorithm that was developed can be run on both contrast-enhanced and non-contrast-enhanced clinical datasets. The method can be applied to automatically extract image HU-contrast characteristics of clinical CT images, not captured in phantom data, whereby enabling quantification and optimization of image quality and contrast administration.
MATERIALS AND METHODS: An automated computer algorithm was developed to measure the distribution of HUs inside four major organs: the lungs, liver, aorta, and spine. These organs were first identified using image processing techniques. Each organ was segmented into multiple regions of interest (ROIs) and characterized in terms of HU values. The medians of the ROI histograms were computed for each dataset. The automated results were validated by assessing their correlation with manual measurements in fifteen contrast-enhanced and fifteen non-contrast-enhanced clinical chest CT datasets. The robustness of the measurements with respect to dependency on image noise and CTDIvol was ascertained. One utility of the approach was further demonstrated in assessing the variability in aorta HUs across 732 patients undergoing noncontrast and contrast-enhanced examinations.
RESULTS: The algorithm successfully measured the histograms of the four organs in both contrast and non-contrast-enhanced chest CT exams. The automated measurements were in agreement with manual measurements with a near unity slope of the relationship between automated and manual measurements with high coefficient of determination (slope = 0.931-1.003, R2 = 0.89-0.99). Organ median HU measurements were found to be largely independent of both image noise and CTDIvol (P > 0.05), as expected. Across patient cases, the program ran successfully across 95% (697/732) of cases. Aorta median HUs demonstrated five times more variability in contrast-enhanced exams compared to that in non-contrast-enhanced exams.
CONCLUSIONS: Patient-specific organ HUs can be measured from clinical datasets. The algorithm that was developed can be run on both contrast-enhanced and non-contrast-enhanced clinical datasets. The method can be applied to automatically extract image HU-contrast characteristics of clinical CT images, not captured in phantom data, whereby enabling quantification and optimization of image quality and contrast administration.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Systemic lupus erythematosus.Lancet 2024 April 18
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app