Criterion validity of the activPAL™ and ActiGraph for assessing children's sitting and standing time in a school classroom setting.
BACKGROUND: Few studies have investigated the accuracy of the ActiGraph (AG) GTX3 accelerometer for assessing children's sitting and standing time. The activPAL (aP) has an inclinometer function that enables it to distinguish between sitting/lying and standing; however, its accuracy for assessing sitting and standing in older children is unknown. This study validated the accuracy of these devices for estimating sitting and standing time in a school classroom against a criterion measure of direct observation (DO).
FINDINGS: Forty children in grades 5-7 wore both devices while being video recorded during two school lessons. AG and aP data were simultaneously collected in 15-s epochs. Individual participant DO and aP data were recorded as total time spent sitting/lying, standing and stepping. AG data were converted into time spent sitting and standing using previously established cut-points. Compared with DO, the aP underestimated sitting time (mean bias = -1.9 min, 95 % LoA = -8.9 to 5.2 min) and overestimated standing time (mean bias = 1.8 min, 95% LoA = -9.6 to 13.3 min). The best-performing AG cut-point across both sitting and standing (<75 counts/15 s) was more accurate than the aP, underestimating sitting time (mean bias = -0.8 min, 95 % LoA = -10.5 to 9.9 min) and standing time (mean bias = -0.4 min, 95% LoA = -9.8 to 9.1 min), but was less precise as evidenced by wider LoAs and poorer correlations with DO (sitting r = 0.86 aP vs 0.80 AG; standing r = 0.78 aP vs 0.60 AG).
CONCLUSIONS: The aP demonstrated good accuracy and precision for assessing free-living sitting and standing time in classroom settings. The AG was most accurate using a cut-point of < 75 counts/15 s. Further studies should validate the monitors in settings with greater inter- and intra-individual variation in movement patterns.
FINDINGS: Forty children in grades 5-7 wore both devices while being video recorded during two school lessons. AG and aP data were simultaneously collected in 15-s epochs. Individual participant DO and aP data were recorded as total time spent sitting/lying, standing and stepping. AG data were converted into time spent sitting and standing using previously established cut-points. Compared with DO, the aP underestimated sitting time (mean bias = -1.9 min, 95 % LoA = -8.9 to 5.2 min) and overestimated standing time (mean bias = 1.8 min, 95% LoA = -9.6 to 13.3 min). The best-performing AG cut-point across both sitting and standing (<75 counts/15 s) was more accurate than the aP, underestimating sitting time (mean bias = -0.8 min, 95 % LoA = -10.5 to 9.9 min) and standing time (mean bias = -0.4 min, 95% LoA = -9.8 to 9.1 min), but was less precise as evidenced by wider LoAs and poorer correlations with DO (sitting r = 0.86 aP vs 0.80 AG; standing r = 0.78 aP vs 0.60 AG).
CONCLUSIONS: The aP demonstrated good accuracy and precision for assessing free-living sitting and standing time in classroom settings. The AG was most accurate using a cut-point of < 75 counts/15 s. Further studies should validate the monitors in settings with greater inter- and intra-individual variation in movement patterns.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app