We have located links that may give you full text access.
A decision model and cost analysis of intra-operative cell salvage during hepatic resection.
BACKGROUND: Intraoperative cell salvage (ICS) can reduce allogeneic transfusions but with notable direct costs. This study assessed whether routine use of ICS is cost minimizing in hepatectomy and defines a subpopulation of patients where ICS is most cost minimizing based on patient transfusion risk.
METHODS: A decision model from a health systems perspective was developed to examine adoption and non-adoption of ICS use for hepatectomy. A prospectively maintained database of hepatectomy patients provided data to populate the model. Probabilistic sensitivity analysis was used to determine the probability of ICS being cost-minimizing at specified transfusion risks. One-way sensitivity analysis was used to identify factors most relevant to institutions considering adoption of ICS for hepatectomies.
RESULTS: In the base case analysis (transfusion risk of 28.8%) the probability that routine utilization of ICS is cost-minimizing is 64%. The probability that ICS is cost-minimizing exceeds 50% if the patient transfusion risk exceeds 25%. The model was most sensitive to patient transfusion risk, variation in costs of allogeneic blood, and number of appropriate cases the device could be used for.
CONCLUSIONS: ICS is cost-minimizing for routine use in liver resection, particularly when used for patients with a risk of transfusion of 25% or greater.
METHODS: A decision model from a health systems perspective was developed to examine adoption and non-adoption of ICS use for hepatectomy. A prospectively maintained database of hepatectomy patients provided data to populate the model. Probabilistic sensitivity analysis was used to determine the probability of ICS being cost-minimizing at specified transfusion risks. One-way sensitivity analysis was used to identify factors most relevant to institutions considering adoption of ICS for hepatectomies.
RESULTS: In the base case analysis (transfusion risk of 28.8%) the probability that routine utilization of ICS is cost-minimizing is 64%. The probability that ICS is cost-minimizing exceeds 50% if the patient transfusion risk exceeds 25%. The model was most sensitive to patient transfusion risk, variation in costs of allogeneic blood, and number of appropriate cases the device could be used for.
CONCLUSIONS: ICS is cost-minimizing for routine use in liver resection, particularly when used for patients with a risk of transfusion of 25% or greater.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app