BMC Urology 2015 July 8
BACKGROUND: The study on SIMS and SMUS as a whole by Alyaa Mostafa et al showed that after excluding the TVT-S sling, there is no significant difference in patient-reported cure rate and objective cure rate between these two methods. In this paper, we systematically evaluate the relevant data on SIMS-Ajust and TVT-O/TOT and further confirm their safety and effectiveness, providing reliable clinical evidence.
METHODS: By searching the Medline, Embase, Scopus, and Web of Science databases and the Cochrane Database of Systematic Reviews combined with manual searches, all reports on randomized controlled trials (RCTs) of single-incision mini-sling (SIMS-Ajust) and transobturator tension-free vaginal tape (TVT-O/TOT) surgeries were collected. Using RevMan 5.2 statistical software, the patient-reported cure rate, objective cure rate, operative time, postoperative pain, lower urinary tract injuries, groin pain, postoperative voiding difficulties, de novo urgency and/or worsening of preexisting surgery, vaginal tape erosion, repeated continence surgery, and other related data on both surgical methods were evaluated.
RESULTS: A total of 154 relevant research reports were retrieved, and five randomized controlled trials were included in this study, involving a total of 678 patients. The meta-analysis results show no significant difference in the patient-reported cure rate and objective cure rate between SIMS-Ajust and TVT-O/TOT [RR = 0.95, 95% CI (0.87 to 1.04), P > 0.05; RR = 0.97, 95% CI (0.90-1.05), P > 0.05]. With respect to operation time and groin pain, SIMS-Ajust outperforms TVT-O/TOT [MD = -1.61, 95% CI (-2.48 to 0.74), P < 0.05; RR = 0.30, 95% CI (0.11 to 0.85), P < 0.05]. In terms of postoperative pain, lower urinary tract injuries, postoperative voiding difficulties, de novo urgency and/or worsening of preexisting surgery, vaginal tape erosion, and repetition of continence surgery, there is no significant difference between SIMS-Ajust and TVT-O/TOT [RR = 0.50, 95% CI(0.18-1.43), P > 0.05; RR = 2.82, 95% CI(0.14-57.76), P > 0.05; RR = 0.64, 95% CI(0.28-1.45), P > 0.05; RR = 1.06, 95% CI(0.66-1.71), P > 0.05; RR = 1.04, 95% CI(0.24-4.45), P > 0.05; RR = 1.64, 95% CI(0.41-6.61), P > 0.05].
CONCLUSIONS: SIMS-Ajust is safe and effective in the treatment of female stress urinary incontinence. Compared with TVT-O/TOT surgery, SIMS-Ajust surgery has the same high objective cure rate and patient-reported cure rate and low incidence of perioperative complications, in addition to its short operative time and low incidence of groin pain. Its long-term efficacy needs further observation.
METHODS: By searching the Medline, Embase, Scopus, and Web of Science databases and the Cochrane Database of Systematic Reviews combined with manual searches, all reports on randomized controlled trials (RCTs) of single-incision mini-sling (SIMS-Ajust) and transobturator tension-free vaginal tape (TVT-O/TOT) surgeries were collected. Using RevMan 5.2 statistical software, the patient-reported cure rate, objective cure rate, operative time, postoperative pain, lower urinary tract injuries, groin pain, postoperative voiding difficulties, de novo urgency and/or worsening of preexisting surgery, vaginal tape erosion, repeated continence surgery, and other related data on both surgical methods were evaluated.
RESULTS: A total of 154 relevant research reports were retrieved, and five randomized controlled trials were included in this study, involving a total of 678 patients. The meta-analysis results show no significant difference in the patient-reported cure rate and objective cure rate between SIMS-Ajust and TVT-O/TOT [RR = 0.95, 95% CI (0.87 to 1.04), P > 0.05; RR = 0.97, 95% CI (0.90-1.05), P > 0.05]. With respect to operation time and groin pain, SIMS-Ajust outperforms TVT-O/TOT [MD = -1.61, 95% CI (-2.48 to 0.74), P < 0.05; RR = 0.30, 95% CI (0.11 to 0.85), P < 0.05]. In terms of postoperative pain, lower urinary tract injuries, postoperative voiding difficulties, de novo urgency and/or worsening of preexisting surgery, vaginal tape erosion, and repetition of continence surgery, there is no significant difference between SIMS-Ajust and TVT-O/TOT [RR = 0.50, 95% CI(0.18-1.43), P > 0.05; RR = 2.82, 95% CI(0.14-57.76), P > 0.05; RR = 0.64, 95% CI(0.28-1.45), P > 0.05; RR = 1.06, 95% CI(0.66-1.71), P > 0.05; RR = 1.04, 95% CI(0.24-4.45), P > 0.05; RR = 1.64, 95% CI(0.41-6.61), P > 0.05].
CONCLUSIONS: SIMS-Ajust is safe and effective in the treatment of female stress urinary incontinence. Compared with TVT-O/TOT surgery, SIMS-Ajust surgery has the same high objective cure rate and patient-reported cure rate and low incidence of perioperative complications, in addition to its short operative time and low incidence of groin pain. Its long-term efficacy needs further observation.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app