We have located links that may give you full text access.
CT pulmonary angiography and CT venography: factors associated with vessel enhancement.
AJR. American Journal of Roentgenology 2007 July
OBJECTIVE: The objective of our study was to determine factors associated with enhancement on CT pulmonary angiography and CT venography.
MATERIALS AND METHODS: Two hundred forty-two cases (83 men and 159 women; mean age, 63 years; age range, 21-92 years) underwent CT pulmonary angiography using a bolus-tracking technique; 189 cases subsequently underwent CT venography 3 minutes after the start of the contrast injection. Two different amounts of nonionic iodine contrast medium were administered: patients weighing > 50 kg who were undergoing both CT pulmonary angiography and CT venography received 450 mg I (group B), whereas all other patients received 300 mg I (group A). The enhancement of vessels was subjectively estimated using a four-point scale, and attenuation values were measured at predetermined levels. Multiple regression analyses were performed with attenuation as the dependent variable and patient age, sex, and weight; amount of contrast medium; scanning delay; and presence of embolism as the independent variables.
RESULTS: The scanning delay for CT pulmonary angiography ranged from 10 to 31 seconds (mean, 19 seconds; SD, 3.3). Subjective estimates of enhancement quality on CT venography were significantly better for group B than for group A (p < 0.001). Multiple regression analyses revealed that body weight and age were the only significant and consistent independent variables associated with enhancement of the pulmonary arteries. The amount of contrast medium, body weight, and scanning delay were the independent variables that were consistently associated with enhancement of the deep veins.
CONCLUSION: The bolus-tracking technique showed relatively small variations in the scanning delay time. Patient age, body weight, and the amount of contrast medium were the important factors associated with vessel enhancement in combined CT pulmonary angiography and CT venography.
MATERIALS AND METHODS: Two hundred forty-two cases (83 men and 159 women; mean age, 63 years; age range, 21-92 years) underwent CT pulmonary angiography using a bolus-tracking technique; 189 cases subsequently underwent CT venography 3 minutes after the start of the contrast injection. Two different amounts of nonionic iodine contrast medium were administered: patients weighing > 50 kg who were undergoing both CT pulmonary angiography and CT venography received 450 mg I (group B), whereas all other patients received 300 mg I (group A). The enhancement of vessels was subjectively estimated using a four-point scale, and attenuation values were measured at predetermined levels. Multiple regression analyses were performed with attenuation as the dependent variable and patient age, sex, and weight; amount of contrast medium; scanning delay; and presence of embolism as the independent variables.
RESULTS: The scanning delay for CT pulmonary angiography ranged from 10 to 31 seconds (mean, 19 seconds; SD, 3.3). Subjective estimates of enhancement quality on CT venography were significantly better for group B than for group A (p < 0.001). Multiple regression analyses revealed that body weight and age were the only significant and consistent independent variables associated with enhancement of the pulmonary arteries. The amount of contrast medium, body weight, and scanning delay were the independent variables that were consistently associated with enhancement of the deep veins.
CONCLUSION: The bolus-tracking technique showed relatively small variations in the scanning delay time. Patient age, body weight, and the amount of contrast medium were the important factors associated with vessel enhancement in combined CT pulmonary angiography and CT venography.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app