We have located links that may give you full text access.
Comparative Study
Journal Article
Lateral-entry pin fixation in the management of supracondylar fractures in children.
BACKGROUND: There has been controversy regarding the optimal pin configuration in the management of supracondylar humeral fractures in children. A crossed-pin configuration may be mechanically more stable than lateral pins in torsional loading, but it is associated with a risk of iatrogenic injury to the ulnar nerve. Previous clinical studies have suggested that lateral pins provide sufficient fixation of unstable supracondylar fractures. However, these studies were retrospective and subject to patient-selection bias.
METHODS: A displaced supracondylar humeral fracture was fixed with only lateral-entry pins in 124 consecutively managed children. Medical records and radiographs were reviewed to identify any complications, including loss of fracture reduction, iatrogenic ulnar nerve injury, infection, loss of motion of the elbow, and the need for additional surgery. In addition, eight displaced supracondylar humeral fractures that had been reduced and fixed with lateral pins at other institutions and had lost reduction were analyzed to determine the causes of the failures.
RESULTS: Sixty-nine children had a type-2 fracture, according to Wilkins's modification of Gartland's classification system; forty-three (62%) of those fractures were stabilized with two pins and twenty-six (38%), with three pins. Fifty-five children had a type-3 fracture; nineteen (35%) of those fractures were stabilized with two pins and thirty-six (65%), with three pins. A comparison of perioperative and final radiographs showed no loss of reduction of any fracture. There was also no clinically evident cubitus varus, hyperextension, or loss of motion. There were no iatrogenic nerve palsies, and no patient required additional surgery. One patient had a pin-track infection. Our analysis of the eight clinical and radiographic failures of lateral pin fixation that were not part of the consecutive series showed that the loss of fixation was due to fundamental technical errors.
CONCLUSIONS: In this large, consecutive series without selection bias, the use of lateral-entry pins alone was effective for even the most unstable supracondylar humeral fractures. There were no iatrogenic ulnar nerve injuries, and no reduction was lost. The important technical points for fixation with lateral-entry pins are (1) maximize separation of the pins at the fracture site, (2) engage the medial and lateral columns proximal to the fracture, (3) engage sufficient bone in both the proximal segment and the distal fragment, and (4) maintain a low threshold for use of a third lateral-entry pin if there is concern about fracture stability or the location of the first two pins.
METHODS: A displaced supracondylar humeral fracture was fixed with only lateral-entry pins in 124 consecutively managed children. Medical records and radiographs were reviewed to identify any complications, including loss of fracture reduction, iatrogenic ulnar nerve injury, infection, loss of motion of the elbow, and the need for additional surgery. In addition, eight displaced supracondylar humeral fractures that had been reduced and fixed with lateral pins at other institutions and had lost reduction were analyzed to determine the causes of the failures.
RESULTS: Sixty-nine children had a type-2 fracture, according to Wilkins's modification of Gartland's classification system; forty-three (62%) of those fractures were stabilized with two pins and twenty-six (38%), with three pins. Fifty-five children had a type-3 fracture; nineteen (35%) of those fractures were stabilized with two pins and thirty-six (65%), with three pins. A comparison of perioperative and final radiographs showed no loss of reduction of any fracture. There was also no clinically evident cubitus varus, hyperextension, or loss of motion. There were no iatrogenic nerve palsies, and no patient required additional surgery. One patient had a pin-track infection. Our analysis of the eight clinical and radiographic failures of lateral pin fixation that were not part of the consecutive series showed that the loss of fixation was due to fundamental technical errors.
CONCLUSIONS: In this large, consecutive series without selection bias, the use of lateral-entry pins alone was effective for even the most unstable supracondylar humeral fractures. There were no iatrogenic ulnar nerve injuries, and no reduction was lost. The important technical points for fixation with lateral-entry pins are (1) maximize separation of the pins at the fracture site, (2) engage the medial and lateral columns proximal to the fracture, (3) engage sufficient bone in both the proximal segment and the distal fragment, and (4) maintain a low threshold for use of a third lateral-entry pin if there is concern about fracture stability or the location of the first two pins.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Management of Diverticulitis: A Review.JAMA Surgery 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app