We have located links that may give you full text access.
Clinical Trial
Journal Article
Randomized Controlled Trial
Haemodynamic responses to the intubating laryngeal mask and timing of removal.
European Journal of Anaesthesiology 2000 December
We determined (a) the haemodynamic responses to intubating laryngeal mask (ILM) airway insertion/intubation and removal in anaesthetized patients, and (b) whether the timing of ILM removal influences these responses. One-hundred and twenty patients without cardiovascular disease were studied. ILM airway insertion/intubation was 5 min after induction with propofol 2 mg kg(-1) and maintenance of anaesthesia with sevoflurane 2% in oxygen 33% and nitrous oxide. Patients were randomly assigned for removal of the intubating laryngeal mask airway at 1, 3 and 5 min after successful intubation. Systolic and diastolic arterial pressures and heart rate were recorded preinduction (baseline), before ILM airway insertion/intubation, at 1-min intervals after insertion/intubation, and at 1-min intervals for 5 min after ILM removal. ILM insertion was successful at the first attempt in all patients, but 46 patients required more than one intubation attempt. Compared with baseline values, there were no increases in systolic or diastolic arterial pressure, but there was an increase in heart rate 1 min after ILM insertion/intubation (9%, P<0.001) and 1 min after ILM removal (8%, P<0.01). There was a significant increase in systolic and diastolic pressures and heart rate 1 min after ILM insertion/intubation (30%, 31% and 15%; all: P<0.002) compared with before ILM insertion/intubation values and 1 min after ILM removal (9%, 8% and 7%; all P<0.05) compared with 1 min after ILM insertion/intubation values. Removal of the ILM 1 min after successful intubation resulted in higher arterial pressure compared with removal at 3 min (systolic arterial pressure 10% higher for 1 min, P = 0.01) and 5 min (systolic arterial pressure 10-23% higher for 3 min, P<0.01; diastolic arterial pressure 10-20% higher for 4 min, P>0.02), but there were no differences in heart rate between groups. Systolic and diastolic arterial pressures were greater if more than one intubation attempt was required. Early removal or multiple intubation attempts did not exceed baseline haemodynamic values. We conclude that ILM insertion/intubation and removal in anaesthetized patients produces little or no haemodynamic response, even if multiple intubation attempts are required. The timing of removal exerts a small, but clinically unimportant influence on these responses.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app