UNLABELLED: In this randomized, controlled cadaver study, we tested the hypothesis that the standard laryngeal mask airway (LMA) and flexible laryngeal mask airway (FLMA) attenuate liquid flow between the esophagus and pharynx. Fifty fresh cadavers were studied in four LMA groups. Ten female cadavers had a size 4 LMA and 10 had a size 4 FLMA; 10 male cadavers had a size 5 LMA and 10 had a size 5 FLMA; 5 male and 5 female cadavers functioned as controls. The chest was opened, and the infusion set of a pressure-controlled, continuous flow pump was inserted into the esophagus and ligated into place. Esophageal pressure was increased in 2-cm H2O increments. Regurgitation pressure was the esophageal pressure at which fluid was first seen with a fiberoptic scope in the hypopharynx (control group) and above the cuff or within the bowl (LMA groups). This was performed in the LMA groups at 0-40 mL cuff volume in 10-mL increments. Mean (95% confidence interval) regurgitation pressure for the control group was 7 (6-8) cm H2O and for the LMA groups combined was 19 (17-20) cm H2O at 0 mL cuff volume, 47 (41-52) cm H2O at 10 mL, 51 (44-55) cm H2O at 20 mL, 52 (45-56) cm H2O at 30 mL, and 52 (45-55) cm H2O at 40 mL. The increase in regurgitation pressure with increasing cuff volume from 0 to 10 mL was statistically significant (P < 0.0001). Regurgitation pressure was higher for the LMA groups at all cuff volumes compared with the control group (P < 0.0001). There were no differences in regurgitation pressure among the LMA groups. We conclude that the correctly placed LMA and FLMA attenuate liquid flow between the esophagus and pharynx.
IMPLICATIONS: We have shown, in cadavers, that the correctly placed standard and flexible laryngeal mask airways attenuate liquid flow between the pharynx and esophagus.
IMPLICATIONS: We have shown, in cadavers, that the correctly placed standard and flexible laryngeal mask airways attenuate liquid flow between the pharynx and esophagus.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app