We have located links that may give you full text access.
Journal Article
Review
The influence of the impression tray on the accuracy of impressions for crown and bridge work--an investigation and review.
British Dental Journal 1998 December 13
OBJECTIVE: To evaluate the accuracy of working casts for crown and bridge restorations made from twin mix putty/wash silicone elastomeric impression materials using different types of stock tray.
DESIGN: A master cast was made from ivorine teeth in a mandibular model. Three teeth were prepared for full crown restorations to simulate a single unit and a three unit bridge. Impressions were taken using four different types of impression tray and two different viscosities of silicone putty, together with a wash. Full metal crowns were constructed and seated on duplicate master casts and measurements made of the marginal discrepancies.
SETTING: The work was carried out in a dental technology laboratory in a university department of restorative dentistry in 1995/1996.
RESULTS: Metal and rigid plastic impression trays showed the least discrepancy (about 50 microns), the latter slightly greater with the normal putty than the soft one. Impressions taken with flexible plastic trays produced considerable discrepancy with both putties, approximately 210 microns and 180 microns respectively.
CONCLUSIONS: Metal and rigid plastic stock trays give greater accuracy in the putty/wash silicone twin mix impression technique compared with flexible plastic ones for crown and bridge work. Those using the latter should be aware of their shortcoming in this respect.
DESIGN: A master cast was made from ivorine teeth in a mandibular model. Three teeth were prepared for full crown restorations to simulate a single unit and a three unit bridge. Impressions were taken using four different types of impression tray and two different viscosities of silicone putty, together with a wash. Full metal crowns were constructed and seated on duplicate master casts and measurements made of the marginal discrepancies.
SETTING: The work was carried out in a dental technology laboratory in a university department of restorative dentistry in 1995/1996.
RESULTS: Metal and rigid plastic impression trays showed the least discrepancy (about 50 microns), the latter slightly greater with the normal putty than the soft one. Impressions taken with flexible plastic trays produced considerable discrepancy with both putties, approximately 210 microns and 180 microns respectively.
CONCLUSIONS: Metal and rigid plastic stock trays give greater accuracy in the putty/wash silicone twin mix impression technique compared with flexible plastic ones for crown and bridge work. Those using the latter should be aware of their shortcoming in this respect.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app