BACKGROUND: With the widespread use of low-dose spiral computed tomography (LDCT) and increasing awareness of personal health, the detection rate of pulmonary nodules is steadily rising.
OBJECTIVE: To evaluate the success rate and safety of two different models of Hook-Wire needle localization procedures for pulmonary small nodule biopsy.
METHODS: Ninety-four cases with a total of 97 pulmonary small nodules undergoing needle localization biopsy were retrospectively analyzed. The cases were divided into two groups: Group A, using breast localization needle steel wire (Bard Healthcare Science Co., Ltd.); Group B, using disposable pulmonary nodule puncture needle (SensCure Biotechnology Co., Ltd.). All patients underwent video-assisted thoracoscopic surgery (VATS) for nodule removal on the same day after localization and biopsy. The puncture localization operation time, success rate, complications such as pulmonary hemorrhage, pneumothorax, hemoptysis, and postoperative comfort were observed and compared.
RESULTS: In Group A, the average localization operation time for 97 nodules was 15.47 ± 5.31 minutes, with a success rate of 94.34%. The complication rate was 71.69% (12 cases of pneumothorax, 35 cases of pulmonary hemorrhage, 2 cases of hemoptysis), and 40 cases of post-localization discomfort were reported. In Group B, the average localization operation time was 25.32 ± 7.83 minutes, with a 100% success rate. The complication rate was 29.55% (3 cases of pneumothorax, 15 cases of pulmonary hemorrhage, 0 cases of hemoptysis), and 3 cases reported postoperative discomfort. According to the data analysis in this study, Group B had a lower incidence of puncture-related complications than Group A, along with a higher success rate and significantly greater postoperative comfort.
CONCLUSIONS: The disposable pulmonary nodule puncture needle is safer and more effective in pulmonary small nodule localization biopsy, exhibiting increased comfort compared to the breast localization needle. Additionally, the incidence of complications is significantly lower.
OBJECTIVE: To evaluate the success rate and safety of two different models of Hook-Wire needle localization procedures for pulmonary small nodule biopsy.
METHODS: Ninety-four cases with a total of 97 pulmonary small nodules undergoing needle localization biopsy were retrospectively analyzed. The cases were divided into two groups: Group A, using breast localization needle steel wire (Bard Healthcare Science Co., Ltd.); Group B, using disposable pulmonary nodule puncture needle (SensCure Biotechnology Co., Ltd.). All patients underwent video-assisted thoracoscopic surgery (VATS) for nodule removal on the same day after localization and biopsy. The puncture localization operation time, success rate, complications such as pulmonary hemorrhage, pneumothorax, hemoptysis, and postoperative comfort were observed and compared.
RESULTS: In Group A, the average localization operation time for 97 nodules was 15.47 ± 5.31 minutes, with a success rate of 94.34%. The complication rate was 71.69% (12 cases of pneumothorax, 35 cases of pulmonary hemorrhage, 2 cases of hemoptysis), and 40 cases of post-localization discomfort were reported. In Group B, the average localization operation time was 25.32 ± 7.83 minutes, with a 100% success rate. The complication rate was 29.55% (3 cases of pneumothorax, 15 cases of pulmonary hemorrhage, 0 cases of hemoptysis), and 3 cases reported postoperative discomfort. According to the data analysis in this study, Group B had a lower incidence of puncture-related complications than Group A, along with a higher success rate and significantly greater postoperative comfort.
CONCLUSIONS: The disposable pulmonary nodule puncture needle is safer and more effective in pulmonary small nodule localization biopsy, exhibiting increased comfort compared to the breast localization needle. Additionally, the incidence of complications is significantly lower.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app