We have located links that may give you full text access.
Impact of atrial fibrillation on 1-year outcome in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy with defibrillator: results from the German DEVICE Registry.
Journal of Thoracic Disease 2024 March 30
BACKGROUND: Atrial fibrillation (AF) is a cardiac arrhythmia frequently documented in patients requiring implantable cardioverter defibrillators (ICDs) and/or cardiac resynchronization therapy with defibrillator (CRT-D). Patients with diagnosed AF at the point of ICD or CRT-D implantation may have an impaired follow-up outcome.
METHODS: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR).
RESULTS: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation.
CONCLUSIONS: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.
METHODS: The German DEVICE I-II registry is a nationwide prospective multicentre database of patients implanted with ICD and CRT-D with clinical follow-up data. We analysed a 1-year follow up of implanted patients with AF and with sinus rhythm (SR).
RESULTS: A total of 4,929 ICD/CRT patients are included in the present analysis: 946 (19.2%) were in AF and 3,983 (80.8%) were SR at time of device implantation. AF patients had a significantly more comorbid profile including older age {72 [interquartile range (IQR), 66-77] vs. 66 (IQR, 56-73) years; P<0.001}, and higher rate of patients with left ventricular ejection fraction <30% (68.2% vs. 61.0%; P<0.001), peripheral artery disease (4.5% vs. 2.7%; P=0.002), diabetes (33.6% vs. 25.5%; P<0.001), hypertension (58.4% vs. 51.1%; P<0.001) and renal failure (22.6% vs. 15.3%; P<0.001). The intra-hospital complication rate was 4.3% in the AF and 3.6% in the SR group (P=0.38). In 1-year follow-up AF patients experienced a significantly higher rate of defibrillator shocks (25% vs. 15.3%; P<0.001). One-year estimated mortality was 10.8% in the AF and 5.9% in the SR group (P<0.001), while estimated 1-year major adverse cardiac and cerebrovascular events (MACCE) rate was 11.2% vs. 7.0% (P<0.001). The effects of AF on electrical shocks and mortality persisted after adjusting for age, sex, advanced New York Heart Association (NYHA) class, severely impaired left ventricular ejection fraction (LVEF), coronary artery disease (CAD), chronic obstructive pulmonary disease (COPD), diabetes mellitus (DM), chronic renal failure (CRF), QRS duration, and type of indication for electronic device implantation.
CONCLUSIONS: Our clinical data on an extended cohort of contemporary patients confirm the significant impact of AF, and its associated comorbidities, upon mortality and major adverse events after implantation of ICD/CRT.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app