Assessing Radiation Exposure and Contrast Agent Utilization: A Comparative Analysis of the Woven EndoBridge Device and Stent-Assisted Coil Embolization for Managing Unruptured Wide-Neck Bifurcation Aneurysms.
Neurointervention 2024 April 15
PURPOSE: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization.
MATERIALS AND METHODS: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated.
RESULTS: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases.
CONCLUSION: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.
MATERIALS AND METHODS: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated.
RESULTS: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases.
CONCLUSION: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.
Full text links
Related Resources
Trending Papers
Mineralocorticoid Receptor Antagonists in Heart Failure: An Update.Circulation. Heart Failure 2024 November 25
Hemodialysis Vascular Access: Core Curriculum 2025.American Journal of Kidney Diseases 2024 December 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app