We have located links that may give you full text access.
Impact on nurse workload and patient satisfaction of atrioventricular junction ablation performed simultaneously with conduction system pacing using a superior approach from the pocket compared to the conventional femoral approach.
European Journal of Cardiovascular Nursing 2024 March 30
AIMS: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve outcomes in patients with symptomatic, refractory atrial fibrillation (AF). Superior approach (SA) from the pocket, via axillary or subclavian vein, has been recently proposed as an alternative to the conventional femoral venous approach (FA) to perform AVJA. In this study we compared the impact of these alternative approaches on the nurse workload (NWL) and on patient satisfaction.
METHODS AND RESULTS: Prospective, observational study, enrolling consecutive patients undergoing simultaneous CSP and AVJA. ElectrophysiologyLaboratory (EP Lab) NWL was calculated with a self-developed model. Ward NWL was calculated using the MIDENF® validated scale. Patient satisfaction was collected using the Hospital Consumer Assessment of Healthcare Provider Systems (HCAHPS) questionnaire. A total of 119 patients were enrolled: in 50, AVJA was primarily attempted with SA, in 69 from FA. Compared to FA, SA was associated with a lower EP Lab NWL (169.8±26.7 vs. 202.7±38.9 minutes; p<0.001), and a lower Ward NWL (474.5±184.8 vs. 808.6±289.9 minutes; p<0.001). Multivariate analysis identified SA as an independent predictor of lower EP Lab NWL (hazard ratio 4.60; p=0.001), and of lower Ward NWL (hazard ratio 45.13; p<0.001). Compared to FA, SA was associated with a higher patient-reported rating regarding the experience during hospital stay (p=0.035), and the overall hospital evaluation (p=0.026).
CONCLUSIONS: In patients undergoing simultaneous CSP and AVJA, the use of a SA for ablation is a valid alternative to conventional FA. Compared to FA, this approach significantly reduces NWL, and is associated with greater patient satisfaction.
METHODS AND RESULTS: Prospective, observational study, enrolling consecutive patients undergoing simultaneous CSP and AVJA. ElectrophysiologyLaboratory (EP Lab) NWL was calculated with a self-developed model. Ward NWL was calculated using the MIDENF® validated scale. Patient satisfaction was collected using the Hospital Consumer Assessment of Healthcare Provider Systems (HCAHPS) questionnaire. A total of 119 patients were enrolled: in 50, AVJA was primarily attempted with SA, in 69 from FA. Compared to FA, SA was associated with a lower EP Lab NWL (169.8±26.7 vs. 202.7±38.9 minutes; p<0.001), and a lower Ward NWL (474.5±184.8 vs. 808.6±289.9 minutes; p<0.001). Multivariate analysis identified SA as an independent predictor of lower EP Lab NWL (hazard ratio 4.60; p=0.001), and of lower Ward NWL (hazard ratio 45.13; p<0.001). Compared to FA, SA was associated with a higher patient-reported rating regarding the experience during hospital stay (p=0.035), and the overall hospital evaluation (p=0.026).
CONCLUSIONS: In patients undergoing simultaneous CSP and AVJA, the use of a SA for ablation is a valid alternative to conventional FA. Compared to FA, this approach significantly reduces NWL, and is associated with greater patient satisfaction.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Systemic lupus erythematosus.Lancet 2024 April 18
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app