Inadvertent septal perforation during conduction system pacing device implant: a case report.
European Heart Journal. Case Reports 2024 March
BACKGROUND: There has been recent growing interest in the use of conduction system pacing (CSP) for both bradycardia and heart failure indications. There remains a paucity of data, however, regarding complications related to the intraventricular septum associated with CSP implant and the management of these events.
CASE SUMMARY: We present a case of a patient with non-ischemic dilated cardiomyopathy presenting for cardiac resynchronization therapy in whom left bundle branch area pacing was complicated with interventricular septal perforation and managed intra-procedurally with repositioning of the lead to provide His bundle pacing (HBP) for QRS correction of underlying left bundle branch block. Post-procedure echocardiography did not show persistent ventricular septal defect. Left ventricular ejection fraction improved from 13% four months before implant to 30% at 32 months post-implant. Corrective HBP pacing thresholds showed a rise at 3-year follow-up.
DISCUSSION: Interventricular septal perforation during CSP is a possible complication during lead fixation. Pre-operative septal assessment with imaging can be helpful to provide important septal anatomical features. Septal perforation can be managed appropriately with lead repositioning intra-procedurally and close follow-up.
CASE SUMMARY: We present a case of a patient with non-ischemic dilated cardiomyopathy presenting for cardiac resynchronization therapy in whom left bundle branch area pacing was complicated with interventricular septal perforation and managed intra-procedurally with repositioning of the lead to provide His bundle pacing (HBP) for QRS correction of underlying left bundle branch block. Post-procedure echocardiography did not show persistent ventricular septal defect. Left ventricular ejection fraction improved from 13% four months before implant to 30% at 32 months post-implant. Corrective HBP pacing thresholds showed a rise at 3-year follow-up.
DISCUSSION: Interventricular septal perforation during CSP is a possible complication during lead fixation. Pre-operative septal assessment with imaging can be helpful to provide important septal anatomical features. Septal perforation can be managed appropriately with lead repositioning intra-procedurally and close follow-up.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app