AIM: In this pilot study, the fracture resistance of hybrid abutments with different restoration lengths was investigated.
MATERIALS AND METHODS: Sixteen monolithic zirconia restorations of an upper right incisor were designed to fit a titanium base abutment. Eight central incisors had a crown length of 8 mm (T1) and the other half a length of 12 mm (T2). All crowns were cemented on the titanium base using a resin cement. After cementation, the samples were placed in a thermocycler for 5000 cycles. Fracture strength was measured using a universal test machine. Deformations and fractures of the samples were investigated.
RESULTS: The mean fracture resistance of T1 was 515 N (SD 96 N, 339-650) and 305 N (SD 57 N, 234-408) for T2 (p < 0.001). Both groups showed deformation of the titanium base, with no significant difference between both groups (p = 0.200). A difference in fracture type (p = 0.013) was observed, with significantly more screw fractures occurring in group T1 (p = 0.026).
CONCLUSION: Within the limitations of this study, hybrid restorations with standard titanium base abutments can withstand forces that have been associated with chewing, irrespective of the crown length. However, the shorter crowns demonstrated more fatal fractures.
MATERIALS AND METHODS: Sixteen monolithic zirconia restorations of an upper right incisor were designed to fit a titanium base abutment. Eight central incisors had a crown length of 8 mm (T1) and the other half a length of 12 mm (T2). All crowns were cemented on the titanium base using a resin cement. After cementation, the samples were placed in a thermocycler for 5000 cycles. Fracture strength was measured using a universal test machine. Deformations and fractures of the samples were investigated.
RESULTS: The mean fracture resistance of T1 was 515 N (SD 96 N, 339-650) and 305 N (SD 57 N, 234-408) for T2 (p < 0.001). Both groups showed deformation of the titanium base, with no significant difference between both groups (p = 0.200). A difference in fracture type (p = 0.013) was observed, with significantly more screw fractures occurring in group T1 (p = 0.026).
CONCLUSION: Within the limitations of this study, hybrid restorations with standard titanium base abutments can withstand forces that have been associated with chewing, irrespective of the crown length. However, the shorter crowns demonstrated more fatal fractures.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app