We have located links that may give you full text access.
Estimation of radiographic joint space of the trapeziometacarpal joint with computed tomographic validation.
Journal of Medical Imaging 2024 March
PURPOSE: Joint space width (JSW) is a common metric used to evaluate joint structure on plain radiographs. For the hand, quantitative techniques are available for evaluation of the JSW of finger joints; however, such techniques have been difficult to establish for the trapeziometacarpal (TMC) joint. This study aimed to develop a validated method for measuring the radiographic joint space of the healthy TMC joint.
APPROACH: Computed tomographic scans were taken of 15 cadaveric hands. The location of a JSW analysis region on the articular surface of the first metacarpal was established in 3D space and standardized in a 2D projection. The standardized region was applied to simulated radiographic images. A correction factor was defined as the ratio of the CT-based and radiograph-based joint space measurements. Leave-one-out validation was used to correct the radiograph-based measurements. A t-test was used to evaluate the difference between CT-based and corrected radiograph-based measurements (α=0.05).
RESULTS: The CT-based and radiograph-based measurements of JSW were 3.61±0.72 mm and 2.18±0.40 mm, respectively. The correction factor for radiograph-based joint space was 1.69±0.41. Before correction, the difference between the CT-based and radiograph-based joint space was 1.43 mm [95% CI: 0.99-1.86 mm; p<0.001]. After correction, the difference was -0.11 mm [95% CI: -0.63-0.41 mm; p=0.669].
CONCLUSIONS: Corrected measurements of radiographic TMC JSW agreed well with CT-measured JSW. With in-vivo validation, the developed methodology has potential for automated and accurate radiographic measurement of TMC JSW.
APPROACH: Computed tomographic scans were taken of 15 cadaveric hands. The location of a JSW analysis region on the articular surface of the first metacarpal was established in 3D space and standardized in a 2D projection. The standardized region was applied to simulated radiographic images. A correction factor was defined as the ratio of the CT-based and radiograph-based joint space measurements. Leave-one-out validation was used to correct the radiograph-based measurements. A t-test was used to evaluate the difference between CT-based and corrected radiograph-based measurements (α=0.05).
RESULTS: The CT-based and radiograph-based measurements of JSW were 3.61±0.72 mm and 2.18±0.40 mm, respectively. The correction factor for radiograph-based joint space was 1.69±0.41. Before correction, the difference between the CT-based and radiograph-based joint space was 1.43 mm [95% CI: 0.99-1.86 mm; p<0.001]. After correction, the difference was -0.11 mm [95% CI: -0.63-0.41 mm; p=0.669].
CONCLUSIONS: Corrected measurements of radiographic TMC JSW agreed well with CT-measured JSW. With in-vivo validation, the developed methodology has potential for automated and accurate radiographic measurement of TMC JSW.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Systemic lupus erythematosus.Lancet 2024 April 18
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app