We have located links that may give you full text access.
Possible use of 2D shear wave liver elastography in new-onset ascites evaluation.
BMC Gastroenterology 2024 Februrary 9
BACKGROUND: No data on the use of 2D shear wave elastography exists regarding the evaluation of the new-onset ascites causality.
AIMS: To determine whether 2D shear wave elastography can help in the non-invasive assessment of the new-onset ascites cause. To assess the applicability of liver stiffness measured by 2D shear wave elastography using Esaote MyLab Nine apparatus in patients with ascites.
METHODS: In 52 consecutive patients with new-onset ascites (January 2020 to October 2021), liver stiffness using 2D shear wave elastography was prospectively measured. The reliable measurements were used for further analysis. Relevant clinical and laboratory data was collected.
RESULTS: The calculated liver stiffness measurement cut-off value of 14.4 kPa held 94% accuracy, 100% sensitivity, and 83% specificity when determining ascites with serum ascites albumin gradient ≥11 g/L. Reliable 2D shear wave elastography success rate was 84%.
CONCLUSIONS: 2D shear wave elastography may potentially be used to differentiate transudative from exudative ascites, especially in patients with portal hypertension and peritoneal carcinomatosis.
AIMS: To determine whether 2D shear wave elastography can help in the non-invasive assessment of the new-onset ascites cause. To assess the applicability of liver stiffness measured by 2D shear wave elastography using Esaote MyLab Nine apparatus in patients with ascites.
METHODS: In 52 consecutive patients with new-onset ascites (January 2020 to October 2021), liver stiffness using 2D shear wave elastography was prospectively measured. The reliable measurements were used for further analysis. Relevant clinical and laboratory data was collected.
RESULTS: The calculated liver stiffness measurement cut-off value of 14.4 kPa held 94% accuracy, 100% sensitivity, and 83% specificity when determining ascites with serum ascites albumin gradient ≥11 g/L. Reliable 2D shear wave elastography success rate was 84%.
CONCLUSIONS: 2D shear wave elastography may potentially be used to differentiate transudative from exudative ascites, especially in patients with portal hypertension and peritoneal carcinomatosis.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app