We have located links that may give you full text access.
Shear Bond Strength of Simulated Single-Retainer Resin-Bonded Bridges Made of Four CAD/CAM Materials for Maxillary Lateral Incisor Agenesis Rehabilitation.
European Journal of Dentistry 2023 December 30
OBJECTIVES: Maxillary lateral incisor agenesis (MLIA), treated orthodontically by space opening, requires complimentary aesthetic rehabilitation. Resin-bonded bridges (RBBs) can be equated as interim rehabilitation until skeletal maturity is achieved to place an implant-supported crown or as definitive rehabilitation in case of financial restrictions or implant contraindications. Scientific evidence of the best material must be confirmed in specific clinical situations. Computer-aided design and computer-aided manufacturing (CAD/CAM) materials are promising versatile restorative options. This study aimed to identify a straightforward material to deliver interim or definitive RBBs for nonprepared tooth replacement in MLIA.
MATERIALS AND METHODS: Single-retainer RBB made from CAD/CAM ceramic blocks (Vita Enamic [ENA], Suprinity [SUP], and zirconia [Y-ZPT]) and a three-dimensional (3D) printed material (acrylonitrile butadiene styrene [ABS]) were evaluated by shear bond strength (SBS) and mode of failure, after adherence to an artificial tooth with RelyX Ultimate used in a three-step adhesive strategy.
STATISTICAL ANALYSIS: The load to fracture (N) was recorded, and the mean shear stress (MPa) was calculated with standard deviations (SD) for each group and compared between materials using boxplot graphics. One-way analysis of variance (ANOVA) followed by the Tukey-Kramer post hoc test was used to compare the differences ( α = 0.05). A meta-analysis focusing on CAD/CAM materials evaluated the magnitude of the difference between groups based on differences in means and effect sizes ( α = 0.05; 95% confidence interval [CI]; Z -value = 1.96). Failure mode was determined by microscopic observation and correlated with the maximum load to fracture of the specimen.
RESULTS: The mean ± SD SBS values were ENA (24.24 ± 9.05 MPa) < ABS (24.01 ± 1.94 MPa) < SUP (29.17 ± 4.78 MPa) < Y-ZPT (37.43 ± 12.20 MPa). The failure modes were mainly adhesive for Y-ZPT, cohesive for SUP and ENA, and cohesive with plastic deformation for ABS.
CONCLUSION: Vita Enamic, Suprinity, Y-ZPT zirconia, and 3D-printed ABS RBBs are optional materials for rehabilitating MLIA. The option for each material is conditioned to estimate the time of use and necessity of removal for orthodontic or surgical techniques.
MATERIALS AND METHODS: Single-retainer RBB made from CAD/CAM ceramic blocks (Vita Enamic [ENA], Suprinity [SUP], and zirconia [Y-ZPT]) and a three-dimensional (3D) printed material (acrylonitrile butadiene styrene [ABS]) were evaluated by shear bond strength (SBS) and mode of failure, after adherence to an artificial tooth with RelyX Ultimate used in a three-step adhesive strategy.
STATISTICAL ANALYSIS: The load to fracture (N) was recorded, and the mean shear stress (MPa) was calculated with standard deviations (SD) for each group and compared between materials using boxplot graphics. One-way analysis of variance (ANOVA) followed by the Tukey-Kramer post hoc test was used to compare the differences ( α = 0.05). A meta-analysis focusing on CAD/CAM materials evaluated the magnitude of the difference between groups based on differences in means and effect sizes ( α = 0.05; 95% confidence interval [CI]; Z -value = 1.96). Failure mode was determined by microscopic observation and correlated with the maximum load to fracture of the specimen.
RESULTS: The mean ± SD SBS values were ENA (24.24 ± 9.05 MPa) < ABS (24.01 ± 1.94 MPa) < SUP (29.17 ± 4.78 MPa) < Y-ZPT (37.43 ± 12.20 MPa). The failure modes were mainly adhesive for Y-ZPT, cohesive for SUP and ENA, and cohesive with plastic deformation for ABS.
CONCLUSION: Vita Enamic, Suprinity, Y-ZPT zirconia, and 3D-printed ABS RBBs are optional materials for rehabilitating MLIA. The option for each material is conditioned to estimate the time of use and necessity of removal for orthodontic or surgical techniques.
Full text links
Related Resources
Trending Papers
Consensus Statement on Vitamin D Status Assessment and Supplementation: Whys, Whens, and Hows.Endocrine Reviews 2024 April 28
The Tricuspid Valve: A Review of Pathology, Imaging, and Current Treatment Options: A Scientific Statement From the American Heart Association.Circulation 2024 April 26
Intravenous infusion of dexmedetomidine during the surgery to prevent postoperative delirium and postoperative cognitive dysfunction undergoing non-cardiac surgery: a meta-analysis of randomized controlled trials.European Journal of Medical Research 2024 April 19
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Systemic lupus erythematosus.Lancet 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app