We have located links that may give you full text access.
Drug-Coated Balloons for De Novo Coronary Artery Lesions: A Meta-Analysis of Randomized Clinical Trials.
Yonsei Medical Journal 2023 October
PURPOSE: Through meta-analysis, we aimed to assess the efficacy and safety of drug-coated balloons (DCB), compared with drug-eluting stents (DES) or uncoated devices, in the treatment of de novo coronary lesions.
MATERIALS AND METHODS: Only randomized controlled trials were included. The primary outcomes were late lumen loss (LLL), target lesion revascularization (TLR), and major adverse cardiac events (MACEs). Subgroup analyses were conducted based on clinical indications, whether DCBs were used with a systematic or bailout stent, and types of DESs.
RESULTS: The present meta-analysis demonstrated that DCBs elicit significantly lower incidences of TLR, MACE, and LLL, compared with uncoated devices, and similar incidences, compared with DESs, in the treatment of de novo coronary lesions. Subgroup analysis indicated that DCBs used with a bailout stent achieved lower incidences of binary restenosis and myocardial infarction, compared with uncoated devices, and provided less LLL than DESs. DCBs showed similar rates of TLR and MACE, with significantly less LLL, than DESs in treating de novo small-vessel diseases. The clinical efficacy of DCBs was similar to that of second-generation DES.
CONCLUSION: Overall, DCB is favored over bare metal stent alone in treating de novo coronary lesions. DCBs appear to be a promising alternative to DESs in the treatment of de novo coronary lesions.
MATERIALS AND METHODS: Only randomized controlled trials were included. The primary outcomes were late lumen loss (LLL), target lesion revascularization (TLR), and major adverse cardiac events (MACEs). Subgroup analyses were conducted based on clinical indications, whether DCBs were used with a systematic or bailout stent, and types of DESs.
RESULTS: The present meta-analysis demonstrated that DCBs elicit significantly lower incidences of TLR, MACE, and LLL, compared with uncoated devices, and similar incidences, compared with DESs, in the treatment of de novo coronary lesions. Subgroup analysis indicated that DCBs used with a bailout stent achieved lower incidences of binary restenosis and myocardial infarction, compared with uncoated devices, and provided less LLL than DESs. DCBs showed similar rates of TLR and MACE, with significantly less LLL, than DESs in treating de novo small-vessel diseases. The clinical efficacy of DCBs was similar to that of second-generation DES.
CONCLUSION: Overall, DCB is favored over bare metal stent alone in treating de novo coronary lesions. DCBs appear to be a promising alternative to DESs in the treatment of de novo coronary lesions.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app