UNLABELLED: This study describes a method to validate a radiation transport model that quantifies the number of DNA double-strand breaks (DSB) produced in the lymphocyte nucleus by internal ex vivo irradiation of whole blood with the radionuclides 90 Y, 99m Tc, 123 I, 131 I, 177 Lu, 223 Ra, and 225 Ac in a test vial using the GATE/Geant4 code at the macroscopic level and the Geant4-DNA code at the microscopic level.

METHODS: The simulation at the macroscopic level reproduces an 8 mL cylindrical water-equivalent medium contained in a vial that mimics the geometry for internal ex vivo blood irradiation. The lymphocytes were simulated as spheres of 3.75 µm radius randomly distributed, with a concentration of 125 spheres/mL. A phase-space actor was attached to each sphere to register all the entering particles. The simulation at the microscopic level for each radionuclide was performed using the Geant4-DNA tool kit, which includes the clustering example centered on a density-based spatial clustering of applications with noise (DBSCAN) algorithm. The irradiation source was constructed by generating a single phase space from the sum of all phase spaces. The lymphocyte nucleus was defined as a water sphere of a 3.1 µm radius. The absorbed dose coefficients for lymphocyte nuclei (dLymph ) were calculated and compared with macroscopic whole blood absorbed dose coefficients (dBlood ). The DBSCAN algorithm was used to calculate the number of DSBs. Lastly, the number of DSB∙cell-1 ∙mGy-1 (simulation) was compared with the number of radiation-induced foci per cell and absorbed dose (RIF∙cell-1 ∙mGy-1 ) provided by experimental data for gamma and beta emitting radionuclides. For alpha emitters, dLymph and the number of α-tracks∙100 cell-1 ∙mGy-1 and DBSs∙µm-1 were calculated using experiment-based thresholds for the α-track lengths and DBSs/track values. The results were compared with the results of an ex vivo study with 223 Ra.

RESULTS: The dLymph values differed from the dBlood values by -1.0% (90 Y), -5.2% (99m Tc), -22.3% (123 I), 0.35% (131 I), 2.4% (177 Lu), -5.6% (223 Ra) and -6.1% (225 Ac). The number of DSB∙cell-1 ∙mGy-1 for each radionuclide was 0.015 DSB∙cell-1 ∙mGy-1 (90 Y), 0.012 DSB∙cell-1 ∙mGy-1 (99m Tc), 0.014DSB∙cell-1 ∙mGy-1 (123 I), 0.012 DSB∙cell-1 ∙mGy-1 (131 I), and 0.016 DSB∙cell-1 ∙mGy-1 (177 Lu). These values agree very well with experimental data. The number of α-tracks∙100 cells-1 ∙mGy-1 for 223 Ra and 225 Ac where 0.144 α-tracks∙100 cells-1 ∙mGy-1 and 0.151 α-tracks∙100 cells-1 ∙mGy-1 , respectively. These values agree very well with experimental data. Moreover, the linear density of DSBs per micrometer α-track length were 11.13 ± 0.04 DSB/µm and 10.86 ± 0.06 DSB/µm for 223 Ra and 225 Ac, respectively.

CONCLUSION: This study describes a model to simulate the DNA DSB damage in lymphocyte nuclei validated by experimental data obtained from internal ex vivo blood irradiation with radionuclides frequently used in diagnostic and therapeutic procedures in nuclear medicine.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app