Add like
Add dislike
Add to saved papers

Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection.

OBJECTIVE: In the majority of patients with chronic type B aortic dissection, there is persistent retrograde flow in the false lumen (FL) through distal re-entry tears. Among several endovascular techniques proposed for FL management, the "Candy Plug" (CP) technique has gained acceptance with good early results. The aim of this study is to report the types and outcomes of open and endovascular reinterventions and identify mechanisms of procedure failure as well as other causes for reinterventions.

METHODS: All patients with type B aortic dissection submitted to thoracic endovascular aneurysm repair and CP implantation for FL embolization from January 2016 to December 2022 at our institution were included in this study. The preoperative, intraoperative, and postoperative data of the primary intervention and secondary reinterventions, when performed, were prospectively collected and retrospectively analyzed. Preoperative and postoperative computed tomography angiography were also analyzed.

RESULTS: During the study period, 33 patients were submitted to thoracic endovascular aneurysm repair and CP implantation. Twenty-three patients (69.7%) showed thoracic FL complete thrombosis with aortic stability or positive remodeling at a mean follow-up of 45 ± 23.1 months. Ten patients (30.3%) underwent aortic reinterventions (male, n = 9; mean age, 60.5 ± 7.6 years). Of these 10 patients, in four patients, complete thrombosis of the FL was never achieved, leading to ongoing perfusion of the FL, defined as "primary failure." The other six patients underwent reinterventions for different causes: two patients, after initial sealing, showed a progressive enlargement of the abdominal FL leading to distal degeneration. One patient showed proximal degeneration, two patients showed a type II thoracoabdominal aortic aneurysm and CP implantation was used as a planned procedure to reduce the extent of the surgical procedure, and one patient had recurrent, intractable back pain despite complete thrombosis of the FL. Reinterventions were open in five cases and endovascular in five. One in-hospital death (postoperative day 27) after a type II thoracoabdominal aortic aneurysm open repair was recorded. In addition, two cases of delayed spinal cord ischemia after open reintervention were recorded: one resulting in permanent paraplegia and one transitory with complete recovery.

CONCLUSIONS: The CP technique was safe and effective; however, a significant rate of aortic-related reintervention was observed. Several mechanisms led to reinterventions either in terms of "primary failure" of the CP or subsequent aneurysmal degeneration. Complex reinterventions were often necessary, with a high rate of major complications in case of open repair. Life-long and closer surveillance might be required in these patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app