We have located links that may give you full text access.
Diagnostic Performance of Endoscopic Ultrasonography with Water-Filled Balloon Method for Superficial Esophageal Squamous Cell Carcinoma.
Digestive Diseases and Sciences 2023 August 5
BACKGROUND: Endoscopic ultrasonography (EUS) is a commonly used tool for preoperative depth diagnosis of superficial esophageal squamous cell carcinoma (ESCC). Probing EUS using the water-filled balloon method is a simple and safe examination.
AIM: The aim of this study was to clarify the diagnostic performance of EUS with the water-filled balloon method for superficial ESCC compared to magnifying narrow-band imaging (ME-NBI).
METHODS: We retrospectively examined 403 lesions in 393 consecutive patients diagnosed with ESCC and evaluated them with ME-NBI and EUS. Clinicopathological findings were collected, and the accuracy of the preoperative diagnosis was compared between ME-NBI and EUS-B. EUS examiners were not blinded to prior ME-NBI results, and EUS results may have been influenced by ME-NBI results.
RESULTS: The pathological tumor depth of the EP/LPM in 152 lesions, MM/SM1 in 130 lesions, and deep submucosa (SM2/SM3) in 121 lesions was examined. The proportion of total lesions with an accurate diagnosis was significantly higher in EUS than in ME-NBI (67.7% versus 62.0%, P = 0.015). When analyzed by clinical depth diagnosis using ME-NBI, the proportion of lesions with an accurate diagnosis was significantly higher for EUS in MM/SM1 (55.7% versus 46.1%, P = 0.033). The sensitivity was significantly higher in EUS for SM2/SM3 lesions (76.0% versus 54.5%, P < 0.001). The accuracy and specificity of EUS, which differentiate MM/SM1 from EP/LPM or SM2/SM3, were significantly higher than those of ME-NBI. The median endoscopic ultrasonography procedure time was approximately 6.5 min.
CONCLUSIONS: EUS with the water-filled balloon method is a safe and straightforward method that can be performed on lesions clinically diagnosed as MM/SM1 using ME-NBI. We retrospectively reviewed lesions in patients diagnosed with ESCC and evaluated them using magnifying endoscopy with narrow-band imaging (ME-NBI) and endoscopic ultrasound using the water-filled balloon method (EUS-B). We conclude that EUS-B can increase the diagnostic accuracy.
AIM: The aim of this study was to clarify the diagnostic performance of EUS with the water-filled balloon method for superficial ESCC compared to magnifying narrow-band imaging (ME-NBI).
METHODS: We retrospectively examined 403 lesions in 393 consecutive patients diagnosed with ESCC and evaluated them with ME-NBI and EUS. Clinicopathological findings were collected, and the accuracy of the preoperative diagnosis was compared between ME-NBI and EUS-B. EUS examiners were not blinded to prior ME-NBI results, and EUS results may have been influenced by ME-NBI results.
RESULTS: The pathological tumor depth of the EP/LPM in 152 lesions, MM/SM1 in 130 lesions, and deep submucosa (SM2/SM3) in 121 lesions was examined. The proportion of total lesions with an accurate diagnosis was significantly higher in EUS than in ME-NBI (67.7% versus 62.0%, P = 0.015). When analyzed by clinical depth diagnosis using ME-NBI, the proportion of lesions with an accurate diagnosis was significantly higher for EUS in MM/SM1 (55.7% versus 46.1%, P = 0.033). The sensitivity was significantly higher in EUS for SM2/SM3 lesions (76.0% versus 54.5%, P < 0.001). The accuracy and specificity of EUS, which differentiate MM/SM1 from EP/LPM or SM2/SM3, were significantly higher than those of ME-NBI. The median endoscopic ultrasonography procedure time was approximately 6.5 min.
CONCLUSIONS: EUS with the water-filled balloon method is a safe and straightforward method that can be performed on lesions clinically diagnosed as MM/SM1 using ME-NBI. We retrospectively reviewed lesions in patients diagnosed with ESCC and evaluated them using magnifying endoscopy with narrow-band imaging (ME-NBI) and endoscopic ultrasound using the water-filled balloon method (EUS-B). We conclude that EUS-B can increase the diagnostic accuracy.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app