Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline.

European Radiology 2023 July 23
OBJECTIVES: This study aims at a fully automatic pipeline for measuring the magnetic resonance parkinsonism index (MRPI) using deep learning methods.

METHODS: MRPI is defined as the product of the pons area to the midbrain area ratio and the middle cerebellar peduncle (MCP) width to the superior cerebellar peduncle (SCP) width ratio. In our proposed pipeline, we first used nnUNet to segment the brainstem and then employed HRNet to identify two key boundary points so as to sub-divide the whole brainstem into midbrain and pons. HRNet was also employed to predict the MCP endpoints for measuring the MCP width. Finally, we segmented the SCP on an oblique coronal plane and calculated its width. A total of 400 T1-weighted magnetic resonance images (MRIs) were used to train the nnUNet and HRNet models. Five-fold cross-validation was conducted to evaluate our proposed pipeline's performance on the training dataset. We also evaluated the performance of our proposed pipeline on three external datasets. Two of them had two raters manually measuring the MRPI values, providing insights into automatic accuracy versus inter-rater variability.

RESULTS: We obtained average absolute percentage errors (APEs) of 17.21%, 18.17%, 20.83%, and 22.83% on the training dataset and the three external validation datasets, while the inter-rater average APE measured on the first two external validation datasets was 11.31%. Our proposed pipeline significantly improved the MRPI quantification accuracy over a representative state-of-the-art traditional approach (p < 0.001).

CONCLUSION: The proposed automatic pipeline can accurately predict MRPI that is comparable with manual measurement.

CLINICAL RELEVANCE STATEMENT: This study presents an automated magnetic resonance parkinsonism index measurement tool that can analyze large amounts of magnetic resonance images, enhance the efficiency of Parkinsonism-Plus syndrome diagnosis, reduce the workload of clinicians, and minimize the impact of human factors on diagnosis.

KEY POINTS: • We propose an automatic pipeline for measuring the magnetic resonance parkinsonism index from magnetic resonance images. • The effectiveness of the proposed pipeline is successfully established on multiple datasets and comparisons with inter-rater measurements. • The proposed pipeline significantly outperforms a state-of-the-art quantification approach, being much closer to ground truth.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app