Add like
Add dislike
Add to saved papers

Impact of Region-of-Interest Delineation on Stability and Reproducibility of Liver SNR Measurements in 68 Ga-PSMA PET/CT.

Objective  This study aims to assess the impact of various regions of interest (ROIs) and volumes of interest (VOIs) delineations on the reproducibility of liver signal-to-noise-ratio (SNRliver) measurements, as well as to find the most reproducible way to estimate it in gallium-68 positron emission tomography ( 68 Ga-PET) imaging. We also investigated the SNRliver-weight relationship for these ROIs and VOIs delineations. Methods  A cohort of 40 patients (40 males; mean weight: 76.5 kg [58-115 kg]) with prostate cancer were included. 68 Ga-PET/CT imaging (mean injected activity: 91.4 MBq [51.2 MBq to 134.1 MBq] was performed on a 5-ring bismuth germanium oxide-based Discovery IQ PET/CT using ordered subset expectation maximization image reconstruction algorithm. Afterward, circular ROIs and spherical VOIs with two different diameters of 30 and 40 mm were drawn on the right lobe of the livers. The performance of the various defined regions was evaluated by the average standardized uptake value (SUV mean ), standard deviation (SD) of the SUV (SUV SD ), SNR liver , and SD of the SNR liver metrics. Results  There were no significant differences in SUV mean among the various ROIs and VOIs ( p  > 0.05). On the other hand, the lower SUV SD was obtained by spherical VOI with diameter of 30 mm. The largest SNR liver was obtained by ROI (30 mm). The SD of SNR liver with ROI (30 mm) was also the largest, while the lowest SD of SNR liver was observed for VOI (40 mm). There is a higher correlation coefficient between the patient-dependent parameter of weight and the image quality parameter of SNRliver for both VOI (30 mm) and VOI (40 mm) compared to the ROIs. Conclusion  Our results indicate that SNR liver measurements are affected by the size and shape of the respective ROIs and VOIs. The spherical VOI with a 40 mm diameter leads to more stable and reproducible SNR measurement in the liver.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app