Characterization of blood-mimicking fluids for echocardiography imaging of ventricular septal defects.
PURPOSE: Ventricular septal defects (VSD) are congenital heart malformations and, in severe cases, they require complex interventions under echocardiography guidance. Heart phantoms can be helpful to train and to understand the complex hemodynamics of VSD. The goal of this study was to characterize the best blood mimicking fluids in such heart phantoms for modelling the hemodynamics of VSD patients using echocardiography.
METHODS: Four fluid compositions were considered. Distilled water was used as a baseline, while the other three fluids were developed based on physical properties of human blood, such as the viscosity and the refractive index. Three bi-ventricular heart phantoms of three different pediatric patients with complex VSD were designed from preoperative CT imaging. Custom molds were printed in 3-D and the anatomical structure was casted in polyvinyl alcohol cryogel. The VSD in each heart phantom were observed using echocardiography and color Doppler imaging was used for the hemodynamic study.
RESULTS: Heart phantoms with blood mimicking fluids of 30% glycerol and 27% glycerol, 10% sodium iodide were found to be anatomically realistic under echocardiography imaging. Hemodynamic parameters such as the pressure gradient and the volume of the shunt were characterized using color Doppler imaging.
CONCLUSION: Proper composition of blood mimicking fluids are important for improving the realism in echocardiographic heart phantoms and they contribute to better understand the complex hemodynamic of VSD under echocardiography.
METHODS: Four fluid compositions were considered. Distilled water was used as a baseline, while the other three fluids were developed based on physical properties of human blood, such as the viscosity and the refractive index. Three bi-ventricular heart phantoms of three different pediatric patients with complex VSD were designed from preoperative CT imaging. Custom molds were printed in 3-D and the anatomical structure was casted in polyvinyl alcohol cryogel. The VSD in each heart phantom were observed using echocardiography and color Doppler imaging was used for the hemodynamic study.
RESULTS: Heart phantoms with blood mimicking fluids of 30% glycerol and 27% glycerol, 10% sodium iodide were found to be anatomically realistic under echocardiography imaging. Hemodynamic parameters such as the pressure gradient and the volume of the shunt were characterized using color Doppler imaging.
CONCLUSION: Proper composition of blood mimicking fluids are important for improving the realism in echocardiographic heart phantoms and they contribute to better understand the complex hemodynamic of VSD under echocardiography.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app