BACKGROUND: An 82-year-old female with a history of atrial fibrillation and repeated episodes of major bleeding on direct oral anticoagulant therapy, with a high risk for thromboembolism and was referred for left atrial appendage closure.
CASE SUMMARY: During the procedure, an unrecognized puncture of the aorta by the transseptal puncture (TSP) needle and inadvertent advancement of the sheath resulted in ascending aorta perforation. This perforation was closed percutaneously using an Amplatzer™ Duct Occluder (ADO). Reversal of heparinization with protamine sulphate was given to avoid intractable bleeding. However, this resulted in thrombus formation and subsequent embolization causing an ST-elevation myocardial infarction. This was treated with balloon dilatation and thrombus aspiration with subsequent Thrombolysis in Myocardial Infarction 3 flow.
DISCUSSION: Inadvertent ascending aorta perforation is a rare yet serious complication that can occur during TSP. Percutaneous closure using an ADO is a viable management option. The reversal of heparin carries a risk of thrombus formation and should be avoided in cases where there is no evidence of overt bleeding.
CASE SUMMARY: During the procedure, an unrecognized puncture of the aorta by the transseptal puncture (TSP) needle and inadvertent advancement of the sheath resulted in ascending aorta perforation. This perforation was closed percutaneously using an Amplatzer™ Duct Occluder (ADO). Reversal of heparinization with protamine sulphate was given to avoid intractable bleeding. However, this resulted in thrombus formation and subsequent embolization causing an ST-elevation myocardial infarction. This was treated with balloon dilatation and thrombus aspiration with subsequent Thrombolysis in Myocardial Infarction 3 flow.
DISCUSSION: Inadvertent ascending aorta perforation is a rare yet serious complication that can occur during TSP. Percutaneous closure using an ADO is a viable management option. The reversal of heparin carries a risk of thrombus formation and should be avoided in cases where there is no evidence of overt bleeding.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app