We have located links that may give you full text access.
Short-chain cyanoacrylates and long-chain cyanoacrylates (Dermabond) have different antimicrobial effects.
Objective: To compare the antimicrobial effect in vitro of a short-chain cyanoacrylate with a long-chain cyanoacrylate (Dermabond, Ethicon, Johnson and Johnson, USA) against bacterial strains.
Methods and analysis: The following bacterial strains were analysed: Staphylococcus aureus , Escherichia coli , Klebsiella pneumonia and Pseudomonas aeruginosa . For each microorganism, standardised sterile discs (6 mm) containing 10 µL of ethyl-cyanoacrylate and 2-octyl cyanoacrylate were applied to the plate. All plates received a blank filter-paper disc with no adhesive (control). All plates were incubated for 24 hours, after which the bacterial inhibitory halos, if present, were measured in millimetres in its greater length.
Results: Inhibitory halos were observed for both adhesives for S. aureus . Inhibition halos were observed only for ethyl-cyanoacrylate for K. pneumoniae and E. coli . No inhibition halo was observed for P. aeruginosa in any sample. The relationship between the total size of the inhibition halos and the diameter of the paper filter for S. aureus was statistically significant compared with 2-octyl cyanoacrylate.
Conclusion: Data shown conclude that ethyl-cyanoacrylate showed in vitro bacteriostatic activity for S. aureus , E. coli and K. pneumoniae . 2-Octyl cyanoacrylate showed in vitro lower bacteriostatic activity only against S. aureus when compared with ethyl-cyanoacrylate. No in vitro bactericidal activity of ethyl-cyanoacrylate or 2-octyl cyanoacrylate was observed.
Methods and analysis: The following bacterial strains were analysed: Staphylococcus aureus , Escherichia coli , Klebsiella pneumonia and Pseudomonas aeruginosa . For each microorganism, standardised sterile discs (6 mm) containing 10 µL of ethyl-cyanoacrylate and 2-octyl cyanoacrylate were applied to the plate. All plates received a blank filter-paper disc with no adhesive (control). All plates were incubated for 24 hours, after which the bacterial inhibitory halos, if present, were measured in millimetres in its greater length.
Results: Inhibitory halos were observed for both adhesives for S. aureus . Inhibition halos were observed only for ethyl-cyanoacrylate for K. pneumoniae and E. coli . No inhibition halo was observed for P. aeruginosa in any sample. The relationship between the total size of the inhibition halos and the diameter of the paper filter for S. aureus was statistically significant compared with 2-octyl cyanoacrylate.
Conclusion: Data shown conclude that ethyl-cyanoacrylate showed in vitro bacteriostatic activity for S. aureus , E. coli and K. pneumoniae . 2-Octyl cyanoacrylate showed in vitro lower bacteriostatic activity only against S. aureus when compared with ethyl-cyanoacrylate. No in vitro bactericidal activity of ethyl-cyanoacrylate or 2-octyl cyanoacrylate was observed.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app