We have located links that may give you full text access.
Validation of lower limb segmental volumetry with hand-held, self-positioning three-dimensional laser scanner against water displacement.
BACKGROUND: Measurement of limb volume is helpful for the evaluation and follow-up of edema, especially in patients with chronic venous insufficiency (CVI) or lymphedema. Water displacement (WD) is the reference method for limb volumetry but is not really suitable for clinical routine. Indirect volumetry based on circumference measurements as well as the more expansive but automatic optoelectronic techniques do not allow detailed measurement at the extremity of the limb.
METHODS: We used a self-positioning laser scanner with dynamic referencing for acquisition and real-time three-dimensional (3D) reconstruction of the lower limb volume in 30 patients with CVI, 30 patients with lymphedema, and 30 healthy controls. Two independent observers performed either one or two laser scans, whose results were tested for intra- and interobserver reproducibility and compared with WD volumetry by Lin's concordance correlation coefficient and Bland and Altman graphic analysis.
RESULTS: Automatic volume calculation from 3D laser scanning data failed in one patient with major lymphedema. Lin's concordance correlation coefficient was 0.99 and 0.98, respectively, for intraobserver no. 1 and no. 2, 0.98 for interobserver reproducibility, and 0.98 and 0.96, respectively, for observer no. 1 and observer no. 2 vs WD comparison. The 3D laser scanning yielded 1.99% precision. Accuracy was 3.12% for observer no. 1 and 2.71% for observer no. 2, laser scanning values being 90 mL higher than WD, which could be attributed to the different posture during measurement.
CONCLUSIONS: Three-dimensional laser scanning is accurate and reproducible, and appears suitable for the evaluation of limb volume in patients with CVI or lymphedema.
METHODS: We used a self-positioning laser scanner with dynamic referencing for acquisition and real-time three-dimensional (3D) reconstruction of the lower limb volume in 30 patients with CVI, 30 patients with lymphedema, and 30 healthy controls. Two independent observers performed either one or two laser scans, whose results were tested for intra- and interobserver reproducibility and compared with WD volumetry by Lin's concordance correlation coefficient and Bland and Altman graphic analysis.
RESULTS: Automatic volume calculation from 3D laser scanning data failed in one patient with major lymphedema. Lin's concordance correlation coefficient was 0.99 and 0.98, respectively, for intraobserver no. 1 and no. 2, 0.98 for interobserver reproducibility, and 0.98 and 0.96, respectively, for observer no. 1 and observer no. 2 vs WD comparison. The 3D laser scanning yielded 1.99% precision. Accuracy was 3.12% for observer no. 1 and 2.71% for observer no. 2, laser scanning values being 90 mL higher than WD, which could be attributed to the different posture during measurement.
CONCLUSIONS: Three-dimensional laser scanning is accurate and reproducible, and appears suitable for the evaluation of limb volume in patients with CVI or lymphedema.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Use of Intravenous Albumin: A Guideline from the International Collaboration for Transfusion Medicine Guidelines.Chest 2024 March 5
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app