Anatomical mismatch of the pulmonary autograft in the aortic root may be the cause of early aortic insufficiency after the Ross procedure.
OBJECTIVE: Early aortic insufficiency can be a problem after the Ross procedure. Anatomical mismatch and an inexact surgical technique may lead to distortion of the normal pulmonary valve geometry and subsequent incorrect leaflet coaptation and valve insufficiency. In this study, we assessed the efficacy of changing and improving the surgical technique to minimize the early pulmonary autograft valve failure. The modifications and the strategy are discussed.
METHODS: From January 1995 to February 1999, a total of 77 adults underwent the Ross procedure for aortic valve replacement at Sahlgrenska University Hospital. The operative technique used was full free-standing aortic root replacement with a pulmonary autograft in all cases. In the first 24 cases, the diameter of the pulmonary roots was seldom measured, eye-balling was used to exclude anatomical mismatch due to a dilated aortic root, and only one attempt of correction was made, which failed. In the other 53 cases, the technique was improved by: (1) reducing the aortic anulus diameter in cases with moderate dilatation; (2) excluding cases with severe dilatation of the aortic annulus; (3) adjusting the diameter of the sinotubular junction of the aorta to the diameter of the sinotubular junction of the pulmonary artery; (4). reimplanting the left ostium in the autograft, and (5) changing the proximal anastomosis technique.
RESULTS: In this study, we had an early aortic incompetence of grade 2 in eight patients among the first 24 patients. In the other 53 patients, postoperative echocardiography at 1 week revealed aortic insufficiency of grade 2 in two patients.
CONCLUSIONS: Aortic insufficiency after the Ross procedure can be minimized by patient selection, intraoperative correction of anatomical mismatch and improved surgical technique.
METHODS: From January 1995 to February 1999, a total of 77 adults underwent the Ross procedure for aortic valve replacement at Sahlgrenska University Hospital. The operative technique used was full free-standing aortic root replacement with a pulmonary autograft in all cases. In the first 24 cases, the diameter of the pulmonary roots was seldom measured, eye-balling was used to exclude anatomical mismatch due to a dilated aortic root, and only one attempt of correction was made, which failed. In the other 53 cases, the technique was improved by: (1) reducing the aortic anulus diameter in cases with moderate dilatation; (2) excluding cases with severe dilatation of the aortic annulus; (3) adjusting the diameter of the sinotubular junction of the aorta to the diameter of the sinotubular junction of the pulmonary artery; (4). reimplanting the left ostium in the autograft, and (5) changing the proximal anastomosis technique.
RESULTS: In this study, we had an early aortic incompetence of grade 2 in eight patients among the first 24 patients. In the other 53 patients, postoperative echocardiography at 1 week revealed aortic insufficiency of grade 2 in two patients.
CONCLUSIONS: Aortic insufficiency after the Ross procedure can be minimized by patient selection, intraoperative correction of anatomical mismatch and improved surgical technique.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app