We have located links that may give you full text access.
Clinical Trial
Comparative Study
Journal Article
Multicenter Study
Multiple regression and vector analyses of laser in situ keratomileusis for myopia and astigmatism.
Journal of Refractive Surgery 1999 September
PURPOSE: To construct a quantitative model relating refractive results to laser settings and other factors.
METHODS: A prospective clinical trial was performed, including 14 surgeons and 523 eyes of 278 patients who desired correction of myopia from -1.00 to -16.00 D (mean, -6.20 D) and astigmatism up to 6.00 D (mean, 1.10 D). Myopia and astigmatism were corrected by laser in situ keratomileusis (LASIK) with sequential spherical and cylindrical ablations using a 5.5-mm ablation zone and a transition zone to 7.0 mm. The Nidek EC-5000 excimer laser and the Chiron Automated Corneal Shaper were used.
RESULTS: Surgically induced refractive changes 3 months after surgery were measured. Spherical ablation by LASIK produced a 19% greater refractive change than that predicted by the Nidek PRK algorithm. The laser setting needed to achieve each 1.00 D of cylinder correction induced 1.30 D change in spherical equivalent refraction (0.80 D more than expected). Patient age and nonlinear effects had small but statistically significant influences on refractive outcome. Sex, left/right eye, and surgeon were not significant factors. Residual variations in spherical equivalent refraction included a 0.50-D constant plus 9% of the predicted spherical equivlanet change. Residual variations in the parallel and orthogonal components of cylinder correction were, respectively, 28% and 13% of the predicted cylinder change plus a 0.30-D constant component. The standard deviation of axis alignment error for cylinder ablation was 3.7 degrees.
CONCLUSIONS: Cylindrical ablation produced a spherical change that was larger than expected. To compensate for this, spherical ablation should be reduced in eyes with astigmatism. Variability in the correction of astigmatism was proportionally larger than that for spherical correction and was primarily due to magnitude rather than axis error.
METHODS: A prospective clinical trial was performed, including 14 surgeons and 523 eyes of 278 patients who desired correction of myopia from -1.00 to -16.00 D (mean, -6.20 D) and astigmatism up to 6.00 D (mean, 1.10 D). Myopia and astigmatism were corrected by laser in situ keratomileusis (LASIK) with sequential spherical and cylindrical ablations using a 5.5-mm ablation zone and a transition zone to 7.0 mm. The Nidek EC-5000 excimer laser and the Chiron Automated Corneal Shaper were used.
RESULTS: Surgically induced refractive changes 3 months after surgery were measured. Spherical ablation by LASIK produced a 19% greater refractive change than that predicted by the Nidek PRK algorithm. The laser setting needed to achieve each 1.00 D of cylinder correction induced 1.30 D change in spherical equivalent refraction (0.80 D more than expected). Patient age and nonlinear effects had small but statistically significant influences on refractive outcome. Sex, left/right eye, and surgeon were not significant factors. Residual variations in spherical equivalent refraction included a 0.50-D constant plus 9% of the predicted spherical equivlanet change. Residual variations in the parallel and orthogonal components of cylinder correction were, respectively, 28% and 13% of the predicted cylinder change plus a 0.30-D constant component. The standard deviation of axis alignment error for cylinder ablation was 3.7 degrees.
CONCLUSIONS: Cylindrical ablation produced a spherical change that was larger than expected. To compensate for this, spherical ablation should be reduced in eyes with astigmatism. Variability in the correction of astigmatism was proportionally larger than that for spherical correction and was primarily due to magnitude rather than axis error.
Full text links
Related Resources
Trending Papers
British Society of Gastroenterology guidelines for the management of hepatocellular carcinoma in adults.Gut 2024 April 17
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Ventilator Waveforms May Give Clues to Expiratory Muscle Activity.American Journal of Respiratory and Critical Care Medicine 2024 April 25
Acute Kidney Injury and Electrolyte Imbalances Caused by Dapagliflozin Short-Term Use.Pharmaceuticals 2024 March 27
Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline - Update 2024.Endoscopy 2024 April 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app