We have located links that may give you full text access.
Modified upside-down technique with Gore tapered iliac limbs for isolated iliac artery aneurysms.
Vascular 2024 March 26
PURPOSE: To describe the off-label use of tapered iliac limbs for the treatment of isolated iliac aneurysms with proximal landing zone significantly larger than distal landing zone.
TECHNIQUE: Inversion of a Gore Excluder tapered leg (W. L. Gore & Associates Inc, Flagstaff, Arizona) with a modified upside-down technique is described. The endoprosthesis, with the olive at the tip of the releasing system previously cut, is inserted in a tip-to-tip fashion into a 15 Fr introducer sheath. The graft is released inside the introducer. An 18 Fr introducer sheath is advanced up to the proximal sealing zone. Following the removal of the 18 Fr dilator, the 15 Fr introducer with the pre-released graft is inserted co-axially into the 18 Fr introducer. A pre-cut 15 Fr dilator is brought up to the endograft and used as a pusher. A pull-back maneuver of the co-axial system, countertractioning with the dilator maintained in position, allows the delivery of the endograft.
CONCLUSION: This technique might offer a feasible option in case of endovascular exclusion of isolated iliac artery aneurysms with significant landing zone diameter mismatch. Extracorporeal inversion is time-saving and could be safer in terms of graft damage and infection.
TECHNIQUE: Inversion of a Gore Excluder tapered leg (W. L. Gore & Associates Inc, Flagstaff, Arizona) with a modified upside-down technique is described. The endoprosthesis, with the olive at the tip of the releasing system previously cut, is inserted in a tip-to-tip fashion into a 15 Fr introducer sheath. The graft is released inside the introducer. An 18 Fr introducer sheath is advanced up to the proximal sealing zone. Following the removal of the 18 Fr dilator, the 15 Fr introducer with the pre-released graft is inserted co-axially into the 18 Fr introducer. A pre-cut 15 Fr dilator is brought up to the endograft and used as a pusher. A pull-back maneuver of the co-axial system, countertractioning with the dilator maintained in position, allows the delivery of the endograft.
CONCLUSION: This technique might offer a feasible option in case of endovascular exclusion of isolated iliac artery aneurysms with significant landing zone diameter mismatch. Extracorporeal inversion is time-saving and could be safer in terms of graft damage and infection.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app