We have located links that may give you full text access.
Utility of Superior Augments in Reverse Shoulder Arthroplasty (Exactech, Equinoxe GPS) without Significant Glenoid Deformity.
Journal of Shoulder and Elbow Surgery 2024 March 20
INTRODUCTION: Superior augment use may help avoid superior tilt while minimizing removal of inferior glenoid bone. Therefore, our goal is to compare superior augments versus no augment baseplates in RSA for patients with rotator cuff dysfunction and no significant superior glenoid erosion.
METHODS: A multicenter retrospective analysis of 145 patients who underwent RSA with intraoperative navigation (Exactech, Equinoxe GPS) and three-year follow-up (mean 32-month follow-up, range 20 to 61 months) who had preoperative superior inclination less than 10 degrees and retroversion less than 15 degrees. Patient demographics, radiographic measurements, surgical characteristics, patient-reported outcomes at preoperative and postoperative visit closest to three years, and adverse events at final follow-up were obtained. Operative time, planned inclination, and planned version of the baseplate were obtained. Chi-square test used to compare categorical variables and student t-test used to compare augment and no augment cohorts.
RESULTS: The study population consisted of 54 superior augment patients and 91 no augment patients. The augment cohort had lower BMI (27.2 vs. 29.4, p-0.023), higher native superior inclination (5.9 vs. 1.4 degrees, p<0.001). No difference between the augment and no augment cohorts was found regarding age (p=0.643), gender (p=0.314), medical comorbidities (p>0.05), surgical indication (p=0.082), and native glenoid version (p=0.564). The augment cohort had higher internal rotation score (4.6 vs. 3.9, p=0.023), all remaining ROM and PROs preoperatively were not significantly different. At final follow-up, active ROM in all planes was not different between the cohorts. Regarding PROs, the postoperative SAS score was significantly higher (78.0 vs. 73.6, p=0.042), and ASES score trended towards higher (83.6 vs. 77.5, p=0.063) in the augment cohort. The augment cohort had significantly lower proportion of patients planned to have superior baseplate tilt (1.9% vs. 14.3%, p=0.012), and had greater mean inclination correction (6.3 vs. 1.3 degrees, p<0.001), compared to no augment cohort. Adverse events were rare, and there was no significant difference found between the augment and no augment cohorts (5.6% vs. 3.3%, p=0.509).
DISCUSSION: Superior augmented baseplate in RSA with minimal superior glenoid erosion is associated with similar ROM and adverse events with somewhat improved postoperative PROs compared to non-augmented baseplates at 3-year follow-up. Additionally, superior augments resulted in a greater proportion of baseplates planned to avoid superior tilt, and trended toward shorter operative times. Further investigation of long-term glenoid baseplate loosening is imperative to fully understand the cost-effectiveness of superior augments in the setting of minimal glenoid deformity.
METHODS: A multicenter retrospective analysis of 145 patients who underwent RSA with intraoperative navigation (Exactech, Equinoxe GPS) and three-year follow-up (mean 32-month follow-up, range 20 to 61 months) who had preoperative superior inclination less than 10 degrees and retroversion less than 15 degrees. Patient demographics, radiographic measurements, surgical characteristics, patient-reported outcomes at preoperative and postoperative visit closest to three years, and adverse events at final follow-up were obtained. Operative time, planned inclination, and planned version of the baseplate were obtained. Chi-square test used to compare categorical variables and student t-test used to compare augment and no augment cohorts.
RESULTS: The study population consisted of 54 superior augment patients and 91 no augment patients. The augment cohort had lower BMI (27.2 vs. 29.4, p-0.023), higher native superior inclination (5.9 vs. 1.4 degrees, p<0.001). No difference between the augment and no augment cohorts was found regarding age (p=0.643), gender (p=0.314), medical comorbidities (p>0.05), surgical indication (p=0.082), and native glenoid version (p=0.564). The augment cohort had higher internal rotation score (4.6 vs. 3.9, p=0.023), all remaining ROM and PROs preoperatively were not significantly different. At final follow-up, active ROM in all planes was not different between the cohorts. Regarding PROs, the postoperative SAS score was significantly higher (78.0 vs. 73.6, p=0.042), and ASES score trended towards higher (83.6 vs. 77.5, p=0.063) in the augment cohort. The augment cohort had significantly lower proportion of patients planned to have superior baseplate tilt (1.9% vs. 14.3%, p=0.012), and had greater mean inclination correction (6.3 vs. 1.3 degrees, p<0.001), compared to no augment cohort. Adverse events were rare, and there was no significant difference found between the augment and no augment cohorts (5.6% vs. 3.3%, p=0.509).
DISCUSSION: Superior augmented baseplate in RSA with minimal superior glenoid erosion is associated with similar ROM and adverse events with somewhat improved postoperative PROs compared to non-augmented baseplates at 3-year follow-up. Additionally, superior augments resulted in a greater proportion of baseplates planned to avoid superior tilt, and trended toward shorter operative times. Further investigation of long-term glenoid baseplate loosening is imperative to fully understand the cost-effectiveness of superior augments in the setting of minimal glenoid deformity.
Full text links
Related Resources
Trending Papers
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app