Add like
Add dislike
Add to saved papers

Implant Stability and Histomorphometric Analysis Comparing Two Different Implant Macrogeometries Placed in Fresh Sockets: An Experimental Study in Sheep.

PURPOSE: The aim of the present animal study was to examine the impact of two implant designs that promote different insertion torque values on implant stability and evaluate, histomorphometrically, the bone healing for immediate implant placement in fresh sockets.

MATERIALS AND METHODS: Twelve female sheep (35.0±5.0kg) and 48 conical Morse-taper dental implants divided into two groups (n = 24 per group): G1 group, where the implants present a design that can provide high insertion torque values; and G2 group, where the implants present a design that can provide low insertion torque values. Both had the same surface treatment, and dimensions (4.0 mm in diameter and 10 mm in length). The first two posterior teeth (both sides) were extracted carefully. Sequentially, there were osteotomies in the mesial socket of each molar tooth. The final implant position was 2 mm below the buccal bone crest level. On the right side, implants of the G1 were placed anteriorly, followed by implants of the G2; and, on the left side, it was the reverse. A digital torquemeter was used to measure the maximum final insertion torque value (f-IT). The initial implant stability quotient (ISQ) was measured immediately after the implant insertion (T0) and immediately after the euthanasia and removing the mandibles with the implants. The animals were euthanized (n=6 animals/ time) at 21 days (T1) and 35 days (T2). The t-test was used to compare statistical differences for each intragroup parameter analyzed. Pearson's correlation was used to analyze possible correlations: f-IT and BIC%, f-IT and ISQ, and ISQ and %BIC.

RESULTS: Regarding the insertion torque, the G1 presented higher values than the G2, with a statistically significant difference (p<0.0001). The ISQ mean values were higher in the B-L direction than those obtained for M-D for both groups. %BIC measurements showed higher values in samples from G2 than G1 at both times and in both directions. New bone, medullary spaces, and collagen matrix had statistical differences between the groups at each evaluation time.

CONCLUSION: Using implants with a modified macrogeometry plays a significant role in implant stability and the healing process of bone tissue around the implant. It is important for clinicians to carefully consider implant macrogeometry when planning dental implant surgery to achieve optimal implant stability and successful osseointegration, mainly in cases of immediate implant placement.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app