We have located links that may give you full text access.
Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs.
Advances in Therapy 2023 October 28
INTRODUCTION: This study investigated patient satisfaction levels in five premium intraocular lenses (IOLs). A secondary aim was to determine whether patient satisfaction was associated with the cataract grade before lens surgery.
METHODS: In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated.
RESULTS: A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004.
CONCLUSION: Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.
METHODS: In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated.
RESULTS: A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004.
CONCLUSION: Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app