Focal Aortic Dissection With Significant Stenosis: A Rare Long Term Complication After TEVAR for Blunt Traumatic Aortic Injury in an Adolescent Patient.
BACKGROUND: Thoracic endovascular aortic repair (TEVAR) in children and adolescents after blunt traumatic aortic injury (BTAI) is being performed increasingly despite no endovascular graft being approved for TEVAR in this population. The smaller diameter of the aorta and access vessels and steeper angle of the aortic arch pose specific challenges for TEVAR in this population. Moreover, data are lacking regarding medium to long term complications. This case presents an adolescent patient who underwent TEVAR for BTAI and suffered a focal aortic dissection several months later.
REPORT: The patient initially presented after a motor vehicle accident and underwent an uncomplicated TEVAR procedure with a 28 mm diameter stent graft (the smallest device available at the time) for Grade III traumatic aortic dissection; the native aortic diameter was 15 mm. The diameter mismatch was accepted due to the lifesaving nature of the procedure. More than 7 months later the patient presented to the emergency department after not being able to urinate for several days and experiencing pain, tingling, and weakness in both legs. Blood samples showed a severe acute kidney injury and computed tomography angiography showed significant aortic stenosis in the distal part of the stent graft, probably caused by a focal dissection. The stenosis and dissection were successfully treated using a Palmaz stent, after which his renal function and extremity complaints recovered.
CONCLUSION: The focal dissection was probably caused by stress on the aortic wall due to the aorta-stent graft diameter mismatch. This case demonstrates that complications after TEVAR in adolescents can arise months after the initial procedure and underscores the need for continued vigilance, especially in cases with an aorta-stent graft mismatch. The threshold for additional imaging and consultation by a vascular surgeon should be low.
REPORT: The patient initially presented after a motor vehicle accident and underwent an uncomplicated TEVAR procedure with a 28 mm diameter stent graft (the smallest device available at the time) for Grade III traumatic aortic dissection; the native aortic diameter was 15 mm. The diameter mismatch was accepted due to the lifesaving nature of the procedure. More than 7 months later the patient presented to the emergency department after not being able to urinate for several days and experiencing pain, tingling, and weakness in both legs. Blood samples showed a severe acute kidney injury and computed tomography angiography showed significant aortic stenosis in the distal part of the stent graft, probably caused by a focal dissection. The stenosis and dissection were successfully treated using a Palmaz stent, after which his renal function and extremity complaints recovered.
CONCLUSION: The focal dissection was probably caused by stress on the aortic wall due to the aorta-stent graft diameter mismatch. This case demonstrates that complications after TEVAR in adolescents can arise months after the initial procedure and underscores the need for continued vigilance, especially in cases with an aorta-stent graft mismatch. The threshold for additional imaging and consultation by a vascular surgeon should be low.
Full text links
Related Resources
Trending Papers
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
2024 AHA/ACC/AMSSM/HRS/PACES/SCMR Guideline for the Management of Hypertrophic Cardiomyopathy: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines.Circulation 2024 May 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app